INSTALLATION
In the ice bin of this appliance you will find the following ac-
cessories: instructions for use, an envelope containing an ice
pallet, a funnel with hose for periodical cleaning, 4 adjustable
feet and washers.
:
— Fit the feet into the receptacles, proceeding as follows:
— Screw the 4 threaded supports on the bottom front and
screw the adjustable feet on the supports~(Fig. 1).
— Place the ice maker ona
stable, level surface and adjust the
feet if necessary.
— Do not install the unit close to a heat source, in a niche, or
leaning against a wall on one side; air must be free to circulate
through the ventilation grids.
— In rooms with an ambient temperature lower than + 10°C or
higher than +32°C, ice cubes production is not guaranteed.
However, at ambient temperatures from + 16°C to +32°C, ice
cubes production can be guaranteed if a tropicalized unit is
installed.
ELECTRICAL CONNECTION
Check that the voltage on the rating plate corresponds to the
voltage in your home (Fig. 2).
Connect the appliance to the mains and ensure that it is work-
ing correctly before storing food.
The earthing of this appliance is compulsory by law.
— The electrical and plumbing connection must be carried out
by a qualified technician, in compliance with local safety regu-
lations.
The manufacturer
will accept
no liability for damage
to
persons or objects arising from the non-observance of this
requirement.
MOULDED PLUGS
For Great Britain only
if the mains lead of the appliance is fitted with a B.S. 1363A 13
Amp fused plug, to change a fuse in this type of plug proceed
as follows:—
-
1. Remove the fuse cover
@ and the fuse (Fig. 1 A).
2. Fit a replacement
fuse which
should
be a BS 1362
13A.A.S.T.A. Item @) (Fig. 1 A).
IMPORTANT:—
— The fuse cover must be refitted when changing a fuse.
— In the event of a fuse cover being misplaced, the plug must
not be used until a correct replacement is fitted.
— Piease ensure that the replacement fuse cover is of the
same colour as the insert or, as the colour embossed in words
on the base of the plug.
— Replacement fuse covers are available from:—
Philips Service,
M.D.A. Spares Sales Department
Waddon Factory Estate
Purley Way
. CROYDON
Surrey
CR9 4DR
Tel: 01 6860505
Please state the colour of the plug insert.
If the fitted plug is not suitable for your socket outlets, it
should be cut off and disposed of, to avoid a possible shock
hazard should it be inserted into a 13A socket elsewhere. A
suitable alternative plug should then be fitted to the cable.
"WARNING-THIS APPLIANCE MUST BE EARTHED"
IMPORTANT: the wires of the mains lead fitted to this appli-
ance are coloured in accordance with the following code:—
GREEN AND YELLOW — EARTH
BLUE — NEUTRAL
BROWN — LIVE
As the colours of the wires in the mains lead fitted to this appli-
ance may not correspond with the coloured markings identi-
fying the terminals in the plug, proceed as follows:—
The wire which is coloured GREEN AND YELLOW must be
connected to the terminal in the plug which is marked with the
letter "E" or by the earth symbol + or coloured GREEN or
GREEN AND YELLOW. The wire which is coloured BLUE must
be connected to the terminal which is marked with the letter
"N" or coloured BLACK. The wire which is coloured BROWN
must be connected to the terminal which is marked with the
letter "L" or coloured RED. If the terminals in the plug are un-
marked or you are in any doubt as to the correct connections,
consult a qualified electrician.
N.B. We recommend the use of a good quality plug.
For the Republic of Ireland only
The information given in respect of Great Britain will frequen-
tly apply, but a third type of plug and socket is also used, the
2-pin, side earth type. In this case, the wire which is coloured
GREEN AND YELLOW must be connected to the EARTH con-
tact, and the other two wires to the two pins, irrespective of
colour. The supply to the socket must be fitted with a 16 amp
fuse. Replacement fuse covers are available from:—
Philips Electrical (Ireland) Ltd.
Service Departments
. Newstead
CLONSKEAGH
Dublin 14
Tel: (01) 693355
2 Kyris Quay
CORK
Tel: (021) 25438
Please state the colour of the plug insert.
PLUMBING CONNECTION
— Connect the water and drain hoses through the rear wall of
the unit (Fig. 3).
— Connect the water inlet hose to a cold water tap, having a3/
4" BSP thread. The outlet hose is to be placed into a drain,
preferably equipped with an S - trap to prevent any odour
back-up. The drain must be at a lower level than the outlet of
the hose from the appliance.
— The outlet hose should be inclined at least 10 degrees so
the water can drain naturally.
— If the water is very hard (rich in calcium and magnesium
salts), insert a softener-filter on the inlet connection between
the tap and the hose. This filter brings the water hardnesstoa
. -
normal value.
— Regenerate or replace the water-softener filter (according
to the type) when the ice cubes are not completely transpar-
ent or production time is increased. This appliance conforms
to EEC directive N° 82/499/EEC on radiointerference.
CONTROLS
Fig. 2:
A) Water drain connection
Fig. 6:
A) Grid fuse
B) Ice-cubes level thermostat
ee