Power Cable Specifications
1 phase
Outdoor unit
AE050RXYDEG
f The power cable is not supplied with Air to water heat pump .
f
f Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord (Code
f
designation IEC:60245 IEC 57 / CENELEC:H05RN-F)
f This Equipment complies with IEC 61000-3-12 .
f
Indoor Unit
(Water Pump, Valve, Wired RMC)
MIM-E03CN
Booster Heater (3kw)
Booster Heater (~3kw)
 + Backup Heater (~3kw)
f The Power cable is not supplied with the heat pump .
f
f For power cable, use the grade H05RN-F materials in 1Ø system .
f
f If you connect Backup Heater at separated power cable, you can reduce wire size . (Please refer to control kit installation
f
manual)
Rated
Voltage Range
Hz
Volts
Min
50
220-240
198
Load
No Heater
240Vac, 50Hz
ENGLISH-31
MCA
Max
Min. Circuit Amps.
264
16 . 0 A
Power cable
Power
supply
mm
,wires
2
1 . 5 / 3
2 . 5 / 3
4 . 0 / 3
1Ø, 220-
6 . 0 / 3
6 . 0 / 3
8 . 0 / 3
MFA
Max. Fuse Amps.
20 . 0 A
MAX. length
Type GL
m
A
<10m
10
10m<L<20m
10
<10m
20
10m<L<20m
20
<10m
40
10m<L<20m
40