Location Requirements; Unit Dimensions And Clearances - Haier HLC1700AXW User Manual

Combination front-load washer and ventiess dryer
Hide thumbs Also See for HLC1700AXW:
Table of Contents

Advertisement

Available languages

Available languages

LOCATION REQUIREMENTS
• The washer must be installed on a solid floor to minimize vibration during the spin cycle.
• The floor should be level with maximum slope of 1' {25mm) under entire washer.
• A suitable location is protected from direct sunlight and heat sources such as
radiators, baseboard heaters, cooking appliances, etc.
• Do not install on carpeting.
• The location must have a grounded electrical outlet located within 4ft. (1.2m) of
the power cord on the back of the washer.
• Hot and cold water faucets must be present within 3ft. (0.9m) of the hot and cold
connections on the washer.
• A water heater must supply hot water with a temperature of at least 120°F (49°C).
• The water pressure should be between 20-100 psi (138-690 kPa).
• This appliance must be operated at room temperature.
• Do not install or operate this appliance in an area where the ambient temperature
can fall below freezing.
UNIT DIMENSIONS AND CLEARANCES
23-7/16'
.•<----------------------------►,
33-9/32
40-23/32'
22-15/32'
M
------------------------- ►.
Minimum Instailation Clearances / Detergent Minimum
Alcove
Closet
Front
n/a
1' (25mm)
Sides and Rear
1' {25mm)
1' {25mm)
Top of Control
1' {25mm)
1' (25mm)
Front ventilation openings are required for closet installations.
24 square inches-3inches from bottom. 48 square inches-3 inch from top.
Louvered door with equivalent openings is acceptable.