14. Installation
Installing Drain Pan
NOTE
• Most codes require placing the water heater on
a suitable drain pan piped to an adequate
drain.
The drain pan helps to prevent property damage
which may occur from condensation or leaks in
the piping connections or tank.
1
Install a suitable drain pan piped to an
adequate drain.
2
Place water heater on drain pan.
3
Ensure the water heater is horizontal using a
spirit level.
NOTE
• Drain valve and T&P relief valve is included in
packing box of the water heater.
They must be installed in the opening provided
for this purpose.
- 60 Hz (R134a)

Installing Drain Valve

Use drain valve included in packing.
1
Apply Teflon tape on the NPT end to prevent
leaking.
2
Install the drain valve in the opening marked
"Drain Valve".