6. To start the motor, press the START key.
After the motor has been magnetized, the motor speed ramps up to the reference value.
While the motor is accelerating, the run status message in the display blinks. When the
motor speed has reached the reference value, the run status message lights
up permanently.
The display shows ReadyRef to indicate that the drive system is operating.
1 L ->
600.0 rpm I
StateINU
ReadyRef
MOTOR SP
0.00 rpm
POWER
1000.0 kW

8.9. Stopping the drive

To stop the motor, press the STOP key.
The motor stops according to the preset stop function. While the motor stops, the status
line of the display shows ReadyRef and the run status message blinks.
1 L ->
600.0 rpm I
StateINU
ReadyRef
MOTOR SP
300.00 rpm
POWER
20.0 kW
As long as the stop sequence is in progress, you can always restart the drive by pressing the
START key.
Just before the motor comes to a standstill, the status line shortly displays Stopping.
1 L ->
600.0 rpm 0
StateINU
Stopping
MOTOR SP
0.00 rpm
POWER
0.0 kW
When the motor has reached zero speed, the status line displays ReadyRun.