12

SPECIFICATIONS

Type
Model No.
ER-X001
ER-X008
Effective charge removal
50mm
80mm
width
0.3 second or
less (Note 1)
Charge removal time
0.5 second or
less (Note 2)
Ion balance
Discharge method
Discharge output voltage
2]RQH JHQHUDWLRQ
0D[LPXP DLU SUHVVXUH
$SSOLFDEOH ÀXLG
Ambient temperature
0 to +50°C (ER-X001 0 to +40°C) (with no dew condensation), For storage: -10 to +65°C
Ambient humidity
 WR +] IUHTXHQF\ (ER-X001  WR +] IUHTXHQF\), 0.75mm amplitude for 2
Vibration resistance
hours in each of XYZ directions (when the power is off)
Shock resistance
Resistance 100 m/s
Enclosure grounding method
Material
Discharge needle: PFA, PC, PPS, Tungsten (Note 7).
High-voltage cable length
1.2m
$SSUR[.
$SSUR[
Weight
370g
Notes: 1) ,Q FRQGLWLRQ RI GLVFKDUJH GLVWDQFH PP FHQWHU RI WKH SURGXFW GLVFKDUJH ZDYHOHQJWK +] DQG DLU VXSSO\  PLQ 03D
In condition of discharge distance 50mm FHQWHU RI WKH SURGXFW GLVFKDUJH ZDYHOHQJWK +] DQG QR DLU VXSSO\
3) In condition of discharge distance 100mm FHQWHU RI WKH SURGXFW GLVFKDUJH ZDYHOHQJWK +] DQG QR DLU VXSSO\
 ,RQ EDODQFH LV DYHUDJH RI SOXV DQG PLQXV $OVR WKH VSHFL¿FDWLRQ YDOXH LV W\SLFDO YDOXH LQ FRQGLWLRQ RI OHVV
than ±10°C ambient temperature change, set the ion balance after 30 minutes of the discharge starting,
switching on the ion balance control function.
5) For ER-X001 WKH GLVFKDUJH IUHTXHQFLHV RI +] +] are accepted. For ER-X008 and high-voltage cables
PP WKH GLVFKDUJH IUHTXHQFLHV RI +] +] +] +] +] DQG +] DUH DFFHSWHG )RU RWKHU KHDGV
+] +] +] +] +] +] +] DQG +] DUH DFFHSWHG
 7KH GULHG FOHDQ DLU LV GULHG GHZ SRLQW HTXLYDOHQW RI ƒ& DQG ¿OWHUHG PHVKVL]H HTXLYDOHQW RI  P DLU
7) Silicon needles are also available. Please contact us for details.
8) High-voltage cables are also available in 1m and 2m lengths. Please contact us for details.
Type
Model No.
Number of charge removal
heads connected
Supply voltage
Current consumption
Indictor
DSC (Discharge)
*UHHQ /(' >/LJKWV XS GXULQJ GLVFKDUJH  EOLQNLQJ GXULQJ GLVFKDUJH VWRSSHG@
CHECK
2UDQJH /(' >/LJKWV XS ZKHQ GLUW ZHDU HWF RI WKH GLVFKDUJH QHHGOH LV GHWHFWHG@
ERROR
5HG /(' >/LJKWV XS ZKHQ DEQRUPDO GLVFKDUJH LV GHWHFWHG@
Level meter
*UHHQ /(' > OHYHOV /LJKWV XS GHSHQGLQJ RQ DPRXQW RI WKH FKDUJH RU LRQ JHQHUDWLRQ@
Output
ALARM, ERROR
COM (COM OUT)
ALARM: ON when dirt or wear of the discharge needle is detected;
OFF when operation is normal.
Output operation
ERROR: OFF when abnormal discharge is detected;
ON when operation is normal.
Short-circuit operation
Intput
Discharge control input (DSC OFF)
COM COM IN
Input operation
Discharge allowed: Open. Discharge halt: 24V or 0V shorted.
Ambient temperature
0 to +50°C (with no dew condensation). For storage: -10 to +65°C
Ambient humidity
AC 1000V, 1 minute, completely charged part/between enclosures
Voltage resistance
Insulation resistance
 0 RU PRUH DW '& 9 FRPSOHWHO\ FKDUJHG SDUWEHWZHHQ HQFORVXUHV
 WR  +] IUHTXHQF\ PP DPSOLWXGH IRU  KRXUV LQ HDFK RI ;<= GLUHFWLRQV
Vibration resistance
Resistance 100 m/s
Shock resistance
Enclosure grounding method
Material
Weight
Power supply / I/O connector: 1 set
Accessories
+RXVLQJ 5 WHUPLQDO 7/ >PDQXIDFWXUHG E\ 0ROH[ ,QF@
*URXQG ZLUH DSSUR[ P SF
Type
Model No.
ER-XCCJ2H
Length
2m
Cable
Weight
$SSUR[ J
13

OPTIONS (sold separately)

Spare discharge needle unit
For ER-X016 to X064
ER-XANT, ER-XANS
Note
AC adapter
ER-XAPS-EX
Power cables
ER-XCC2 2m
ER-XCC5 5m
Note: ER-XANT of the spare discharge needle unit is a tungsten needle, and ER-XANS is a silicon needle. Use it com-
bined correctly with the head.
Head
ER-X016
ER-X032
ER-X048
160mm
320mm
480mm
1 second or less (Note 3)
±30V or less (Note 2) (Note 3) (Note 4)
Pulse AC method (Note 5)
$SSUR[ 9
0.01ppm or less (Note 2) (Note 3)
0.5MPa
Air (dried clean air) (Note 6)
35 to 65%RH. For storage: 35 to 85%RH
2
DSSUR[ *   WLPHV LQ HDFK RI ;<= GLUHFWLRQV ZKHQ WKH SRZHU LV RII
Floating
Main unit enclosure: PPS, Stainless steal (SUS).
Head mounting bracket: Stainless steal (SUS).
0.5m Note 8
$SSUR[
$SSUR[
$SSUR[
330g
410g
530g
650g
Controller
ER-XC02
0D[LPXP  XQLWV
24V DC±10%
450mA or less when connecting 1 heads.
800mA or less when connecting 2 heads.
Displays status of Head 1 and 2
PhotoMOS relay output
‡ 0D[LPXP ORDG FXUUHQW P$
‡ Applied voltage: 30VDC or less (between output-output common)
‡ Residual voltage: 1.5V or less (at load current of 100mA)
Equipped (automatic reset type)
Photo coupler input
Input current: 4.5mA or less
Input voltage: 30VDC or less (between input-input common)
,QSXW LPSHGDQFH DERXW N 
35 to 65%RH. For storage: 35 to 85%RH
AC 500V, 1 minute, charged part/between F.G.
(when power is off)
2
DSSUR[ *   WLPHV LQ HDFK RI ;<= GLUHFWLRQV
(when the power is off)
Floating
Enclosure: ABS
$SSUR[ J
Head connection cable
ER-XCCJ5H
ER-XCCJ10H
5m
Cabtyre cable with connectors at both ends
$SSUR[ J
$SSUR[ J
For ER-X008
For ER-X001
ER-XANT2
ER-XANT1
For ER-X016 to X064
Discharge part protective cover
ER-XACVR
14
CE MARKED PRODUCT
This product is CE marked product.
Contact for CE
ER-X064
Panasonic Marketing Europe GmbH Panasonic Testing Center
640mm
Winsbergring 15, 22525 Hamburg,Germany
15

DIMENSIONS (Unit: mm)

<Head part>
Head
28.5
9.4
40
$SSUR[
780g
2-6.5
6.2
High-voltage unit
2-6.5 Mounting holes
38
18
<Controller>
35 mm wide DIN rail
10m
<Head connection cable>
9.1
KWWSSDQDVRQLFQHWLGSLGV[JOREDO
2YHUVHDV 6DOHV 'LYLVLRQ +HDG 2I¿FH
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN
Please refer to the instruction manual of the head part for the form dimensions of ER-X001.
B
A
40
E
D
C
ER-X008
ER-X016
A
40
120
B
106
194
C
138
226
D
150
238
E
163
251
6
180
17
160
31
2-4.5 Mounting holes
10.5
170
162
192
103.5
9.1
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
28.5
9.4
22
18
ER-X032
ER-X048
ER-X064
280
440
600
354
514
674
386
546
706
398
558
718
411
571
731
High-voltage cable ø6.9
(16) (16)
For head 1
For head 2
Head connection
connector
S12B-PUDSS-1
[Manufactured by
5.2
-67 0IJ &R /WG@
18
53
39
10
7
2-5.0
Mounting
holes
(23.2)
<Power cable>
19.6