Advertisement

This INSTALLATION AND OPERATION
MANUAL explains the proper use of your new
Sharp Air Conditioner. Read these instructions
carefully before installing or operating your air
conditioner. The INSTALLATION AND OP-
ERATION MANUAL should be kept in a safe
place for handy reference.
As an ENERGY STAR Partner, Sharp Electronics has determined that these products meet the ENERGY
STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be
at least 10% more efficient than the minimum Federal standard.
AF-S50EX
AF-S60EX

ROOM AIR CONDITIONER

INSTALLATION AND OPERATION
MANUAL
CONTENTS
FOR YOUR PROTECTION ....................
• CHECK WINDOW AREA ........................ 4
• LOCATlON .............................................. 4
• ACCESSORIES ...................................... 5
• SUGGESTED TOOLS ............................ 5
• INSTALLATION ....................................... 6
• CAUTION FOR USE ............................ 8
• NOTES ON OPERATION .................... 9
• ENERGY EFFICIENCY TIPS ............... 9
• PARTS NAMES ................................... 10
• COOLING OPERATION ...................... 11
• SLEEP OPERATION ........................... 13
• ON TIMER OPERATION ..................... 14
• OFF TIMER OPERATION .................... 15
PAGE
2
3

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AF-S50EX

  • Page 1: Table Of Contents

    ERATION MANUAL should be kept in a safe place for handy reference. As an ENERGY STAR Partner, Sharp Electronics has determined that these products meet the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard.
  • Page 2: For Your Protection

    Address City State Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation...
  • Page 3: Consumer Limited Warranty

    Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash-type windows. Minimum opening (Without mounting kit) " (450mm) Window opening from stool to lower sash bottom must be 14 or more.
  • Page 5: Accessories

    ACCESSORIES Accessories Right closure assembly Left closure assembly Window sash foam seal Window sash foam seal (adhesive type) Bottom gasket Screws (L=1", 25.4mm) Screws (L= ", 10mm) Base pan angle Remote control Battery SUGGESTED TOOLS 1. Screw driver (medium size Phillips) 2.
  • Page 6: Installation

    INSTALLATION INSTRUCTIONS INSTALLATION WARNING: Make sure the unit is turned off and unplugged before working. Cut the window sash foam seal (adhesive type) to the proper length and attach it to the underside of the window sash. Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels.
  • Page 7 Insert the closure assemblies on both sides into the rails of the jamb. Loosen screws on both sides of the cabinet, then hang the base pan angle on and secure the screws again. Secure the base pan angle to the sill by using the hole of the front side on the angle with one screw.
  • Page 8: Precautions

    PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manua • Make sure the unit is the correct capacity for the area you want to cool. •...
  • Page 9: Notes On Operation

    Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out. • Turn off air conditioner when no one is home.
  • Page 10: How To Operate

    HOW TO OPERATE PARTS NAMES UNIT CONTROL PANEL Receiver window for remote control signal Display SLEEP indicator SELECTOR pad COOL indicator TEMPERATURE setting pad Lower temp. ---- Raise temp. ---- Front Cabinet Air Inlet (Indoor Side) Horizontal Louvers Vertical Louvers Air Outlet (Indoor Side) Control Panel Rear Cabinet...
  • Page 11: Cooling Operation

    COOLING OPERATION TO CHANGE FAN SPEED AND OPERATION MODE NOTES ON OPERATION MODE: COOL indicator MODE HIGH COOL light on MED COOL light on LOW COOL light on HIGH FAN light off MED FAN light off LOW FAN light off •...
  • Page 12: To Change Temperature Setting

    HOW TO OPERATE TO CHANGE TEMPERATURE SETTING NOTE: • In fan only (HIGH FAN, MED FAN, LOW FAN) operation, the temperature display will go off and the temperature setting cannot be changed. • In cases of power outages or when the unit is disconnected; when the power is restored or the unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH COOL.
  • Page 13: Energy Saver Operation

    ENERGY SAVER OPERATION During normal operation, the thermostat automatically controls cooling and the fan runs continu- ously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops.
  • Page 14: On Timer Operation

    HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time.
  • Page 15: Off Timer Operation

    OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.
  • Page 16: Using The Remote Control

    HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two size-AA (R6) batteries. Open the battery compartment cover. Insert and slide the batteries into the compartment, making sure polarities are properly aligned. Close the cover. NOTES: • The battery life is approximately one year with normal use. •...
  • Page 17 OPERATING WITH THE REMOTE CONTROL POWER TEMP. SELECTOR OFF TIMER SLEEP Light absorbing material is used for the Power ON/OFF and TEMP buttons. Keep the remote control in a lighted place for several hours in order for the buttons to absorb light.
  • Page 18: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter before starting the unit.
  • Page 19: Before Calling For Servlce

    BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Is the fuse blown or the circuit breaker tripped? •...