Download Print this page

Sony IPELA SNC-CH110 Installation Manual page 2

Network camera
Hide thumbs Also See for IPELA SNC-CH110:

Advertisement

Rope (not
supplied)/
防坠绳
(未附带)
Network cable
(straight, not
supplied)/
10BASE-T/
网线(直通,
100BASE-TX
未附带)
PoE supported device
(such as a hub)/
PoE 支持设备(例如集
线器)
Front/
正面
Top/
顶部
46 (1
/
)
13
16
93 (3
3
/
)
4
Unit: mm (inches)/
单位:mm(英寸)
English
Location and Function of Part
Front • Top
 Lens
A fixed-focus lens is mounted.
 Tripod screw hole
Use this screw hole when attaching the
camera to a tripod (screw: 1/4", 20 UNC).
You can attach a tripod to either the
U1/4", 20 UNC
U1/4", 20 UNC
top or bottom of the camera.
= 4.5 mm - 7 mm
= 4.5 mm - 7 mm
(ISO standard) (with the
(ISO standard) (with the
screws fastened)
screws fastened)
Caution
Use the mounting screw whose length is 4.5 mm (³/₁₆ inch) – 7 mm
(⁹/32 inch) only. Use of other screws may cause improper mounting and
damage parts inside the camera.
 Model name label
This label shows device information, such as the model name and serial
number.
Rear
 LAN connector (PoE) [RJ-45]
Use network cable STP, category-5 (SNC-CH110) or network cable UTP,
category-5 (SNC-CH210) for network communications and PoE* power
supply.
 See "connect to network" for connection.
(* PoE: The acronym for Power over Ethernet. IEEE 802.3af standard
compliant devices.)
 Fall-prevention rope mounting hole
When installing the camera on a ceiling or a wall. Be sure to secure a fall-
prevention rope (not supplied) to this hole for safety.
 MONITOR out connector [AV minijack]
Output the composite video signal from the camera.
Monitor out is used when you adjust the view angle.
 Before use, see the procedure from "Using the monitor out".
Note
Before use, it is necessary to connect to the PC and change the system
setting.
 NTSC/PAL switch
Switching the video output.
 Sensor input
Sensor input
Signal
cable color
Red
Sensor input+
White
Sensor input– (GND)
 For details on function and required settings, refer to the User's Guide
stored in the supplied CD-ROM.
 For the wiring, see "Wiring diagram for sensor input".
 POWER indicator (Green)
When the power is supplied to the camera, the camera starts checking
the system. If the system is normal, this indicator lights up.
 NETWORK indicator (Green/Orange)
The indicator lights up or flashes when the camera is connected to the
network. The indicator is off when the camera is not connected to the
network. When 100BASE-TX is connected, the indicator turns green.
When 10BASE-T is connected, the indicator turns orange.
 Reset switch
To reset the camera to the factory default settings, turn on the power to
the camera while holding down this switch with a pointed object.
 MAC Address label
Indicates the MAC address of this camera.
Installation
Caution
When installing the camera on a ceiling or a high location, be sure to secure a
fall-prevention rope (not supplied) to the camera for safety.
Attaching the fall-prevention rope
When you install the camera on a ceiling or a high location, be sure to attach
a fall-prevention rope (not supplied) to prevent the camera from falling.
Thread the fall-prevention rope through the hole on the rear of the camera,
and then fix it to the junction box on the ceiling or wall with a screw (not
supplied), as in the illustration.
For details about the fall-prevention rope, please consult the store of
purchase or an authorized Sony dealer.
Note
Take care to avoid any short-circuits with the rope when you attach it.
Connection
Connect to the Network
Connect the LAN connector of the camera to a PoE* supported device (such
as a hub) using the network cable (straight, not supplied).
The electrical power is supplied through the network cable. For details, refer
to the instruction manuals of the PoE supported devices.
Note
Be sure to use shielded LAN cables for the SNC-CH110.
(* PoE: The acronym for Power over Ethernet. IEEE 802.3af standard compliant
devices.)
Wiring diagram for sensor input
Mechanical switch/open collector output device
Camera inside
Outside
3.3 V
10 kΩ
2.2 kΩ
Mechanical
10 kΩ
switch
Sensor input +
Sensor input −
or
10 kΩ
(GND)
Open collector output
device
GND
GND
GND
Using the monitor out
Setting the view angle of the monitor out
1
Make sure the POWER indicator lights up.
2
Select the installation tab in system setting menu, then set
monitor out to On.
3
Connect the AV cable to the monitor out [AV minijack].
4
Adjust the view angle.
5
Select the installation tab in system setting menu, then set
monitor out to Off.
6
Disconnect the AV cable.
 The system setting is changed from PC.
For details on required settings, see the User's Guide stored in the
supplied CD-ROM.
Notes
Connect the AV cable when the POWER indicator lights up.
Be aware that the system performance may be influenced, if the monitor
out is set to On. Be sure to set it to Off and disconnect the AV cable.
Using the front sheet
If you want to turn the front logo upside down (for correct orientation after
installation), use the supplied front sheet (with logo).
If you want to hide front logo, use the supplied front sheet (without logo).
If you want to make a change after using the initial front sheet, the second
front sheet can be used over the first one.
Specifications
Compression
Video compression format
JPEG/MPEG4/H.264
Maximum frame rate
JPEG/MPEG4/H.264: 30 fps (1280 × 720)
Camera
Image device
SNC-CH110
1/3.8 type CMOS
Effective picture elements:
Approx. 1,280,000
SNC-CH210
1/2.8 type CMOS (Exmor)
Effective picture elements:
Approx. 3,270,000
Minimum illumination
SNC-CH110
5.0 lx (AGC (max.)/50 IRE (IP))
SNC-CH210
2.0 lx (AGC (max.)/50 IRE (IP))
Lens
Focal length
SNC-CH110: 2.34 mm
SNC-CH210: 3.3 mm
Maximum relative aperture
F2.8
View angle
SNC-CH110
Horizontal: 80.7°/Vertical: 63.3°
(4:3 mode)
SNC-CH210
Horizontal: 88°/Vertical: 65°
(4:3 mode)
Minimum object distance
0.5 m
Interface
LAN (PoE)
10BASE-T/100BASE-TX, auto negotiation
RJ-45
Sensor input
1 port: make contact and break contact
switchable
Monitor out
NTSC/PAL
1.0 Vp-p, 75 ohms, unbalanced, sync
negative AV minijack*
* Use AV cable with mini-plug at AV4
terminal.
Others
Power
IEEE802.3af compliant (PoE system) Class 1
Power consumption
2.4 W
Operating temperature
0°C~50°C (32°F to 122°F)
Storage temperature
–20°C to +60°C (–4°F to +140°F)
Operating humidity
20% to 80% (Non-condensing)
Storage humidity
20% to 95%
Dimensions (diameter × length) 
ø44 mm × 93 mm (1 3/4 inches ×
3 3/4 inches)
Mass
Approx. 100 g (3.5 oz)
Supplied accessories
CD-ROM (User's Guides, and supplied
programs) (1)
Sensor input cable (1)
Front sheet (with logo) (1)
Front sheet (without logo) (1)
Installation Manual (this document) (1)
Design and specifications are subject to change without notice.
Recommendation of Periodic Inspections
In case using this device over an extended period of time, please have it
inspected periodically for safe use.
It may appear flawless, but the components may have deteriorated over
time, which may cause a malfunction or accident.
For details, please consult the store of purchase or an authorized Sony
dealer.
*
*
*
*
*
*
*
*
1
1
2
2
3
3
4
4
5
5
6
6
*
*
*
*
~
~
ø
ø

Advertisement