Installation manual 1 Safety Precautions WARNING. This appliance is intended only for drying textiles washed in water. DO NOT MODIFY THIS APPLIANCE. Servicing shall be carried out only by authorized personnel. Only authorized spare parts shall be used. When performing service or replacing parts, the power must be disconnected. A-weighted emission sound pressure level at workstations: <70 dB Additional requirements for the following countries: AT, BE, BG, HR, CY, CZ, DK, EE, FI, FR, DE, GR, HU, IS, IE, IT, LV, LT, LU, MT, NL, NO, PL, PT, RO, SK, SI, ES, SE, CH, TR,...
Installation manual 3 Delivery The cabinet is delivered unassembled as two transport units, an upper part the contains the dehumidifier unit and a lower part of the cabinet. 180 kg 1400 1220 fig.W01355 Wood packaging Packaging, upper part Packaging, package 1 Packaging, package 2 Shoe rack Hangers, installed...
Installation manual 4 Assembly instructions, cabinet part Figure number Heading Assembly pieces Installation kit, cabinet part Recommended tools Placement and leveling of the bottom plate Installation of rear piece Installation of side plates Assembly of front beam (over the doors) Installation of front and rear beam Installation of air duct Installation of flat drying frame...
Installation manual 5 Dehumidifier unit 5.1 Unpacking Removal all packing materials. Do not use sharp objects, as this could damage the product. Unpacked, the dehu- midifier unit weighs 82 kg. Packaging materials such as plastic and styrofoam should be kept out of reach of children. 5.2 Installation kit for dehumidifier unit fig.W01372 Screw M8x20 (4).
Page 25
Installation manual Upper part as seen from behind fig.W01373 Lamp Hose nipple Door cable Lower part with door cable connected fig.W01374A The fully assembled right door has an installed door cable (3) connected to the control panel in the door. Bend it away so it is not damaged when the upper part is placed on the lower part.
Page 26
Installation manual The installation kit contains four air tubes that are used when installing the upper part. • Remove the cover plugs (A) and insert the air tubes (B) at the ends. Twist the air tubes so they lock into place. •...
Page 27
Installation manual fig.W01375A Fastening screw for upper part M8x20 (4) Fastening screw 4x9,5 SHEETtracs for air duct (2) Sealing strip Air duct...
Installation manual 6 Attachment to the wall The cabinet must be attached to the wall to prevent tipping. The installation kit contains two angle brackets that are mounted on the upper part of the drying cabinet as illustrated. Use the provided screws. The brackets have grooves for adjustment to the wall. Secure the cabinet to the wall.
Installation manual 7 Electrical connection The electrical installation may only be performed by qualified personnel. Electrical connection of the appliance must be done in accordance with electrical safety regulations. We recommend that the mains cable be equipped with a ground fault interrupter. The manufacturer disclaims all liability if the electrical connection is not done in the manner prescribed in this manual.
Installation manual 7.2 Connecting to ELS Vision Connect the network cables GND, RX, TX, 24V to the terminal block. Connect the neutral position switch to terminal block positions 1 and 2. fig.W01529 Activate the connection to ELS Vision as follows: •...
Installation manual 7.3 Connecting to an external payment system Connect the cables from the external payment system to terminal block positions 1 and 2 "EXT SW". fig.W01529 Activate the connection to the external payment system as follows: • Activate the programming mode: Press STOP + SUN + BUTTERFLY. Press the Stop button first and then the pro- gram selection buttons simultaneously.
Installation manual 8 Connection to floor drain The cabinet is delivered from the factory with a condensation drain connection on the left side of the cabinet. The connection can be moved to the right side following the instructions below Thread the supplied condensation hose on the hose nipple and route it to the floor drain. Thread on the hose without hose clip.
Installation manual 9 Move the condensation connection to the right side The cabinet is delivered from the factory with a condensation drain connection on the left side. The connection can be moved to the other side following the instructions below. 1.
Installation manual 10 Language setting • Activate the programming mode: Press STOP + SUN + BUTTERFLY. Press the Stop button first and then the pro- gram selection buttons simultaneously. The display lights up and shows "ACCESS 1000". To be able to move on, code 9191 must replace the code 1000.
Installation manual 11 Function check May only be performed by qualified personnel. A function check must be performed when the installation is finished and before the appliance can be used. Whenever a repair has been made, a function check must be performed before the appliance can be used again. •...
Installation manual 12 Disposal information 12.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.
Page 40