299(+47) 278(+55) 278(+55) 278(+55) NET WEIGHT (Kg) 24.4 39.1 The performance tests are based on the EN14511、EN14825. After installation SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT ROOM AIR CONDITIONER OUTDOOR UNIT Johnson Controls-Hitachi Air Conditioning Wuhu Co., Ltd.
Page 3
WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS 1. Scope 2. Object parts ..3. Items to be observed in handling Fig. 1 Conductive container Ω Fig. 2 Body earth...
Page 4
Ω Fig.3 Grounding of the working table Fig.4 Grounding a solder iron Ω...
Page 7
Figure showing the installation of Outdoor unit MODEL RAC-DJ18PHAE/RAC-DJ25PHAE/RAC-DJ35PHAE The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit The clearances of the unit from top, left, right should be kept below 10m.
Page 8
Figure showing the installation of Outdoor unit MODEL RAC-RAC-DJ50PHAE The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit should be kept below 10m. The clearances of the The connecting pipe, no matter unit from top, left, right...
CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-DJ18/25/35PHAE OUTDOOR UNIT Air outlet Drain hole More than NOTE: 1.For outdoor unit installation , allow at least 2 sides of space around the unit ensure ventilation flue. 2.The connecting pipe , should all the insulated with insulation pipe. 3.Piping length is within 20m.
Page 10
CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-RAC-DJ50PHAE OUTDOOR UNIT Unit : mm Drain hole Drain hole Drain hole More than NOTE: 1.For outdoor unit installation , allow at least 2 sides of space around the unit ensure ventilation flue. 2.The connecting pipe , should all the insulated with insulation pipe. 3.Piping length is within 20m.
MAIN PARTS COMPONENT THERMOSTAT (Room temperature Thermistor) FAN MOTOR Fan Motor Specifications RAC-DJ18/25/35/50PHAE DC : 160 - 380V BLU : BLUE YEL : YELLOW BRN : BROWN WHT : WHITE GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED BLK : BLACK PNK : PINK VIO : VIOLET...
Page 12
COMPRESSOR MOTOR Compressor Motor Specifications RAC-DJ50PHAE RAC-DJ18/25/35PHAE ASD088CKPA7JK6B GTD130UKQA8JT6 220 - 350 V 220 - 350 V 827W 1350W 2M = 2.084 2M = 1.354 RAC-DJ18/25/35PHAE RAC-DJ50PHAE CAUTION...
WIRING DIAGRAM MODEL RAC-DJ18/25/35/50PHAE ※2 SOME MODELS NOT NEED TO INSTALL THE CIRCUITS IN DASH DOT. ※3 F1 CURRENT VALUE BE DIFFERENT FOR DIFFERENT MODELS.
BLOCK DIAGRAM MODEL RAC-DJ18/25/35/50PHAE Power source OUTDOOR UNIT Compressor Power circuit drive circuit Indoor unit Compressor Indoor / Outdoor motor interface circuit Control power circuit Outdoor DC fan motor Reset circuit drive circuit Outdoor Fan motor ODU Heat Exchange thermistor verheat thermistor Reversing valve drive circuit...
Procedure for Disassembly and Reassembly <OUTDOOR UNIT> Remove P.W.B. fixing screws (1 locations) and MODEL RAC-DJ18/25/35PHAE radiation fin fixing screws (8 locations), and 1. Electr cal Part remove the P.W.B. from the support. (1) Remove the upper cover fixing screws and lift the Radiation fin fixing screw cover to remove it.
Page 21
(4)Lower the right side of the front cover and pull (6)Set the electrical box upside down. it forward. Then, remove the cover from the hook. Fig. 9 (7)Remove each connector and earth cable from the lead wire. Then,remove the electrical box. Fig.
Page 25
4.Reversing valve control circuit This model reversing valve control used to control the relay ON/OFF of the revesing valve, and also control the coil of the reversing valve ON/OFF. The relay ON/OFF has different type when in the different operation mode. You can see each operation mode as fllows.
Page 26
ODU Heat Exchange thermistor CN30 HIC P.W.B R267 ODU Heat Exchange thermistor C226 R311 Ooutdoor Ooutdoor The ODU heat exchanger thermistor circuit measure the heat exchanger intermediate temperature of the outdoor unit, and micro computer estimate the pressure of compressor according to the temperature data. When the pressure reach the internal set value of the micro computer, the micro computer will adjust the speed of the compressor to protect the pressure of compressor.
Page 30
RAC-DJ50PHAE DB602 300-330 In case of compressor inverter circuit (Q901~Q906) Compressor inverter circuit (Q901~Q906) Constitute by some inverter parts.
Page 34
4.Reversing valve control circuit This model reversing valve control used to control the relay ON/OFF of the revesing valve, and also control the coil of the reversing valve ON/OFF. The relay ON/OFF has different type when in the different operation mode. You can see each operation mode as fllows.
Page 35
ODU Heat Exchange thermistor CN30 HIC P.W.B R267 ODU Heat Exchange thermistor C226 R311 Ooutdoor Ooutdoor The ODU heat exchanger thermistor circuit measure the heat exchanger intermediate temperature of the outdoor unit, and micro computer estimate the pressure of compressor according to the temperature data. When the pressure reach the internal set value of the micro computer, the micro computer will adjust the speed of the compressor to protect the pressure of compressor.
SERVICE CALL Q&A Cold air comes out during a To improve the dehumidification efficiency performs dehumidifying operation. quiet fan operation. Therefore the air is cold and it is not a malfunction.
Page 43
DISCHARGE, PROCEDURE AND POWER SHUT OFF METHOD FOR POWER CIRCUIT WARNING Caution Voltage of about 320 V is charged between the terminal of smoothing capacitors. During continuity check for each circuit part of the outdoor unit, be sure to discharge the smoothing capacitors.
Page 46
SELF-DIAGNOSIS LIGHTING MODE RAC-DJ18/25/35/50PHAE LED(※1) INDICATION LED INDICATION DURING STOP DANGER (DC350V) DURING COMPRESSOR OPERATE SELF-DIAGNOSE LD301 CHECKING POINT&REPAIR METHOD OPERATION CONTENT LD301 CUT THE POWER SOURCE AND WAIT MORE THAN STATUS NO POWER SUPPLY AT TERMINAL “L - N” → CHECK POWER CABLE 10 MINUTES BEFORE SERVICING WORK.
Page 47
After turning on the power, perform air purification by remote control. If there is not the air purifier and operating function,setting to 32 by the remote control,and operate in the cooling mode. Correct the power supply. fan motor Check fan motor refer to DC fan motor control circuit.
Page 48
LD301 blinking frequency each 0.25 second, please check it carefully. ・ ・ voltage detection circuit or current Circuit abnormal detection circuit).
Page 53
How to run the product with the outdoor unit test switch If the indoor electrical parts is out of order and if you wish to run the outdoor unit 1. Turn on the outdoor terminal boards L and N (220-230 V AC). 2.
Page 54
TO OPERATE THE OUTDOOR UNIT INDEPENDENTLY L RAC-DJ18/25/35PHAE RAC-DJ50PHAE ※ Do not operate for 5 minutes or more. ※...