Download Print this page
Panasonic WhisperComfort FV-04VE1 Quick Start Manual

Panasonic WhisperComfort FV-04VE1 Quick Start Manual

Hide thumbs Also See for WhisperComfort FV-04VE1:

Advertisement

Quick Links

FV-04VE1 Two 4" Ducts
Panasonic WhisperComfort Spot Energy Recovery
Ventilator (ERV) offers a revolutionary way to provide
balanced ventilation. Affordable and easy to install,
WhisperComfort is energy effi cient and provides fresh
ventilated air while maintaining Indoor Air Quality (IAQ).
Spot balanced ventilation
Low-rate continuous run ideal for multi-family dwellings
Ideal for new air tight homes built to meet energy
effi ciency standards
UL listed for ceiling or wall mount installation
Exchange capillary core recovers heat, energy and
moisture
Balances air pressure inside the house

Advertisement

loading

Summary of Contents for Panasonic WhisperComfort FV-04VE1

  • Page 1 FV-04VE1 Two 4" Ducts Panasonic WhisperComfort Spot Energy Recovery Ventilator (ERV) offers a revolutionary way to provide balanced ventilation. Affordable and easy to install, WhisperComfort is energy effi cient and provides fresh ventilated air while maintaining Indoor Air Quality (IAQ).
  • Page 2 Panasonic WhisperComfort Spot ERV uses two 4 inch ducts – one to exhaust stale air and the other to supply fresh air from outdoors. Its low, continuous run ensures volatile organic compounds (VOC’s) are vented out and replaced with fresh air.
  • Page 3 Use 2 WhisperComfort or 1 WhisperComfort and Use WhisperComfort set at 40 CFM 1 WhisperGreen ® * WhisperGreen are Panasonic exhaust fans with variable speed DC motor and ® built-in controls. Ideal for both bathroom intermittent ventilation and whole house continuous run ventilation.
  • Page 4 Switch labels are provided for convenience to attach to Open 1 hr. the selected switches. Close 30 m. Panasonic offers the FV-WCSW21-W/A(White/Almond) 2 function switch as part of the WhisperControl product Open 1 hr. line. This commercial grade on/off multiswitch 19ºF...
  • Page 5: Installation

    Elbow (FV-WC04VE1) connect the ERV unit directly to the Y shaped adapter of the exterior wall cap, you can skip this step. Fig. 11-4 Typical Wall Cap Installation Alternative Panasonic Solution EXHAUST SUPPLY Supply hood Exhaust hood should include should include...
  • Page 6 13-1/2” 13-1/2” to 16” 8-5/8 in. 4-1/2 in. 20-3/4” 16-3/4” FV-04VE1 FV-WC04VE1 FV-EB04VE1 Panasonic Eco Solutions of North America For Order Information Eco Products Division PHONE: 866-292-7299 Two Riverfront Plaza FAX: 888-553-0723 Newark, NJ 07102 ventfans@us.panasonic.com us.panasonic.com/ventfans Design and specifi cations subject to change without notice.