7SR210 7SR220 Argus
Overcurrent Protection Relay
Description
The 7SR210 and 7SR220 are a new generation of non-
directional and directional overcurrent protection relays,
built on years of numeric relay protection experience with
the Argus family of products. Housed in 4U high, size E6 or
E8 cases, these relays provide protection, control, monitor-
ing, instrumentation and metering with integrated input and
output logic, data logging & fault reports. Communication
access to relay functionality is via a front USB port for local
PC connection or rear electrical RS485 port for remote con-
nection. Additional rear port options are available.

Function Overview

Standard Functionality – 7SR210 & 7SR220
37
Undercurrent
46BC
Broken Conductor / Load Unbalance
46NPS Negative Phase Sequence Overcurrent
49
Thermal Overload
50
Instantaneous Overcurrent
50G/N
Instantaneous Earth Fault
50BF
Circuit Breaker Fail
50AFD Arc Flash Detector
51
Time Delayed Overcurrent
51G/N
Time Delayed Measured Earth Fault /SEF
60CTS-I CT Supervision
64H
High Impedance REF
74TC/CC Trip/Close Circuit Supervision
81HBL2 2nd Harmonic Block/Inrush Restraint
51c
Cold Load Pickup
8 Settings Groups
Password Protection – 2 levels
User Programmable Logic
Self Monitoring
Siemens Protection Devices Limited
Standard Functionality - 7SR220 Directional Relay
21FL
Fault Locator
21LB
Load Blinder
27/59
Under/Over Voltage
47
Negative Phase Sequence (NPS) voltage
51V
Voltage Controlled Overcurrent
59N
Neutral Voltage Displacement
60CTS
CT Supervision
60VTS
VT Supervision
67/50
Bi-Directional Instantaneous Overcurrent
67/50G/N
Bi-Directional Instantaneous Earth Fault
67/51
Bi-Directional Time Delayed Overcurrent
67/51G/N
Bi-Directional Time Delayed Earth Fault
81
Under/Over Frequency
Optional Functionality – 7SR210 & 7SR220
79 + 25
Auto Reclose + Check Sync

User Interface

20 character x 4 line backlit LCD
Menu navigation keys
3 fixed LEDs
8 or 16 Programmable Tri-colour LEDs (Option)
6 Programmable Function Keys each with Tri-colour LED
(Option)

Monitoring Functions

Standard Monitoring – 7SR210 & 7SR220
Primary current phases and earth
Secondary current phases and earth
Positive Phase Sequence (PPS) Current
Negative Phase Sequence (NPS) Current
Zero Phase Sequence (ZPS) Current
Binary Input/Output status
Trip circuit healthy/failure
Time and date
Starters
Fault records
Event records
Waveform records
Circuit breaker trip counters
I
t summation for contact wear
2
Demand metering
Standard Monitoring - 7SR220 Directional Relay
Direction
Frequency
Primary line and phase voltages
Secondary voltages
Apparent power and power factor
Real and reactive power
W Hr forward and reverse
VAr Hr forward and reverse
Historical demand record
Positive phase sequence (PPS) Voltage
Negative phase sequence (NPS) Voltage
Zero phase sequence (ZPS) Voltage
2