Service Diagnosis - Haier Z/N-Series Service Manual

Wall mounted type dc inverter free match
Table of Contents

Advertisement

11 Service Diagnosis

11.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2. When a signal transmission error occurs between the indoor and outdoor units. In either case, conduct the
diagnostic procedure described in the following pages.
11.2 Parameter of primary electronic appliance
N
O
N
a
m
e
1
Compressor
2
Fan
motor
3
Reactor
4
4-way
valve
P
a
a r
m
t e
r e
Rated
voltage:220-230V
Rated
current:8.4A
Rated
frequency:50/60Hz
Resistance:0.93Ω
Rated
voltage: DC 224-336V
Rated
current:0.236-0.288A
Rated
frequency:50/60Hz
Rated
power:41W
Rated
voltage:29.4V±10%
Rated
current:18A
Rated
frequency:50Hz
Rated
inductance:5.2mH±10%
Rated
voltage:220-240V
Rated
frequency:50/60Hz
Power :4.5/3.5W
P
c i
u t
e r
47
Service diagnosis
Domestic air conditioner

Advertisement

Table of Contents
loading

This manual is also suitable for:

2u18fe2era