Planning the RF300 system
4.3 Installation guidelines
Transponder
MDS D423
MDS D424
MDS D524
MDS D425
MDS D525
MDS D428
MDS D528
MDS D460
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metal-
2)
lic surroundings.
84
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal; dis-
tance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal; dis-
tance all round 20 mm
Without metal
1)
On metal; distance 0 mm
Flush-mounted in metal; dis-
tance all round 20 mm
ANT 3 without
ANT 3 on metal
metal
100
100
125
125
125
143
100
100
23
23
17
13
100
100
89
100
71
54
100
93
93
93
93
93
100
93
33
33
33
33
System Manual, 07/2017, C79000-G8976-C345-07
ANT 3 flush-
mounted in
metal
(40 mm all-
round)
93
121
136
94
21
10
100
71
36
83
83
83
90
20
17