Step 3) Attach the PAB90x-1 board to the MCB900 board
• Disconnect the power cable from the MCB900 board
• Set the jumper on the MCB900 board from "Reset" to "RUN"
• Plug the PAB90x-1 programming board onto the MCB900. Make sure all
28 pins align correctly. Be aware of the locations for pin position 1 for
when you insert a device later on (see image below).
PIN 1
NOTE: If you have an MCB900 board without a 28-pin DIP socket, please use the
included 28-pin DIP socket and solder it into the MCB900 board.
NOTE: There are 3 jumpers on the PAB90x-1 board, these have to be all set to the
position "ICP_xxx" closest to the edge of the board in order for the LPC90x to enter
ICP mode.
Your MCB900 / PAB90x-1 programming hardware is now set up.