Siemens SIMATIC IFP1200 Basic Operating Instructions Manual page 38

Hide thumbs Also See for SIMATIC IFP1200 Basic:
Table of Contents

Advertisement

Installing and connecting the device
3.3 Connecting the device
Procedure (SIMATIC IFP1200 Basic C)
1. Switch off the 24V DC power supply.
2. Ensure that the cable ends of the power
supply lines are fitted with end sleeves.
3. Fasten the end of a connecting cable L+ and
a connecting cable M with the supplied
power supply connector.
4. Connect the power supply connector to the
relevant terminal on the device.
5. Connect the remaining L+ and M ends with
the respective terminals on the 24V DC
power supply.
Note
For SIMATIC IFP1200 Basic C, to meet the requirements of IP65 protection degree for the
entire device, two-core cable is required, and the outer diameter of cable sheath ranges from
6 mm to 7.2 mm.
For SIMATIC IFP1200 Basic C, before connecting the power supply, remove the terminal
compartment cover.
For SIMATIC IFP1200 Basic C, after connecting the cable of power supply, DisplayPort, Type A
and Type B, use cable ties (3mm × 100mm) to secure the connected cables to the strain
relief.