Lowering the Hopper without Power
1. Install the cylinder lock.
2. Ensure that the tub is empty.
3. Place a large drain pan under the hydraulic-
manifold block.
4. Remove the access panel.
5. Disconnect the hose fittings in the manifold
block and allow the fluid to drain into the pan.
Note:
recycling center.
6. Connect the hose fittings.
7. Use a hoist or have 2 people hold up the
hopper and remove the cylinder lock.
8. Carefully lower the hopper.
9. After making repairs, install the hoses to the
manifold block fittings.
10. Add hydraulic fluid.
3461-433A
Dispose of the used fluid at a certified
G384891
G384893
G385185
Page 4–9
Operation: After Operation