Siemens SIMATIC IPC277G PRO Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC277G PRO:
Table of Contents

Advertisement

Quick Links

SIMATIC IPC277G PRO
SIMATIC
Industrial PC
SIMATIC IPC277G PRO
Operating Instructions
02/2022
A5E51373692-AA
Preface
Overview
Safety instructions
Installing and connecting
the device
Commissioning the device
and device functions
Operating the device
Expanding and assigning
parameters to the device
Maintaining and repairing
the device
Technical specifications
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC277G PRO

  • Page 1 SIMATIC IPC277G PRO Preface Overview SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC277G PRO Commissioning the device and device functions Operating the device Operating Instructions Expanding and assigning parameters to the device Maintaining and repairing the device...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    USB stick in PDF format (in multiple languages). Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC277G PRO in this documentation. Instead of the specific names of the operating system, we are using the abbreviation "Windows 10"...
  • Page 4 Preface History The following editions of these operating instructions have been published: Edition Comment 02/2022 First edition SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 5: Table Of Contents

    Opening and closing the terminal compartment cover............36 3.4.2.2 Connecting the 24 V DC power supply ................39 3.4.2.3 Connecting the protective conductor ................. 41 3.4.3 Connecting peripheral equipment ..................42 3.4.4 Connect device to networks ....................42 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 6 8.2.3 ESD guideline ........................83 Dimension drawings ......................86 8.3.1 Dimension drawing of 12" device ..................86 8.3.2 Dimension drawing of 15" device ..................89 8.3.3 Dimension drawing of 19" device ..................92 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 7 Markings and symbols ........................119 Overview ......................... 119 Safety ..........................119 Operator controls......................119 Certificates, approvals and markings ................120 Interfaces ........................121 List of abbreviations .......................... 123 Glossary ............................. 127 Index ..............................135 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 8 Table of contents SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 9: Overview

    Overview Product description 1.1.1 Overview Features SIMATIC IPC277G PRO provides high-level industrial functionality. • Compact design • IP65 degree of protection • High degree of ruggedness • Maintenance-free operation • Expansion with system components The range has been expanded by the PRO device with fully dust-proof, splash-proof with IP65 degree of protection and Enclosure Type 4X (indoor use only) / Type 12;...
  • Page 10: Configuration Plan

    Overview 1.1 Product description The SIMATIC IPC277G PRO is available in the following device versions, which differ in regard to the display size, operating method and optional expansions: PRO device with capacitive multi-touch screen • Display: – 12" display, resolution: 1280 × 800 pixels –...
  • Page 11: Structure Of The Devices

    Front view and side view The front view on the left is the standard mounting position, side view on the right. ① Display with multi-touch screen ② Enclosure ③ Backplane cover ④ Terminal compartment cover SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 12 Rear view - device version "pedestal/extension components" and "support arm without extension components". ① Backplane cover ② Terminal compartment cover ③ Mechanical interface for mounting/base adapter Rear view - device version "support arm and extension components" ① Terminal compartment cover SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 13: Interfaces And Operator Controls

    2 × USB 3.1 port, high current ⑦ On/Off switch Switch on (position " I "); Switch off (position "O") ⑧ Connection terminal 24 V DC Connection terminal inserted in delivered condition power supply (X80) SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 14: Accessory Kit

    Mechanical interface to the PRO device ④ Cover ⑤ Mechanical interface to support arm or stand You can find information on mounting the PRO device at Support arm or stand without extension components (flange on top) (Page 29). SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 15: Round Tube Adapter

    Ring groove for fastening on PRO device with setscrews ③ Mechanical interface to support arm You can find information on mounting the PRO device at Support arm and extension components (round tube) (Page 32). SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 16: Adapter Set For Support Arm And Stand Mounting Of Pro Device

    Adapter set for support arm and stand mounting of PRO device The PRO device can be mounted on systems from third-party vendors (see section "Mounting the device (Page 28)"). For this you will need the Siemens base adapter (see Base adapter (Page 14)) and a proprietary adapter set.
  • Page 17 In addition, different operator controls such as emergency stop, selector switch, illuminated pushbutton, keyswitch, indicator light or RFID reader are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. You can find information on "System components for PRO device Extension Units" on the Internet (https://support.industry.siemens.com/cs/us/en/view/109742323).
  • Page 18: Accessories

    Overview 1.5 Accessories Accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Additional accessories can be found on the Internet: • Industry Mall (https://mall.industry.siemens.com) • Expansion components and accessories (https://w3.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories)
  • Page 19: Safety Instructions

    The installation of expansions can damage the device, machine or plant. Device and system expansions can violate safety rules and regulations regarding radio interference suppression. If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 20 • Replace the lithium battery only with an identical battery or types recommended by SIEMENS (article number: A5E48370874). • For any requirements on product maintenance, contact Siemens Technical support (Page 115). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 21: Security Information

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 22: Data Protection

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 23: Installing And Connecting The Device

    A damaged packaging indicates that ambient conditions have already had an impact on the device. The device might be damaged. Do not dispose of the original packaging. Pack the device during transportation and storage. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 24: Identification Data Of The Device

    The device can be clearly identified with the help of this identification data in case of repairs or theft. Enter the identification data in the following table: Identification data Source Value Serial number Product label S VP ... Order number Product label 6AV7886-1..Production version Product label SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 25 Ethernet address 2 (MAC) Ethernet address 3 (MAC) Product label The following image shows the product label on the SIMATIC IPC277G PRO as an example. The manual is delivered online, you can download the document from Central technical support (https://support.industry.siemens.com/cs/ww/en/).
  • Page 26: Permitted Mounting Positions

    Device version "pedestal/extension components (flange at bottom)" Operating position Deviation from the vertical ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 27 Deviation from the vertical ① Inclined ≤ 45° ② Vertical 0° Device version "support arm and extension components (round tube)" Operating position Deviation from the vertical ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 28: Mounting The Device

    Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
  • Page 29: Support Arm Or Stand Without Extension Components (Flange On Top)

    Requirements • All packaging components and protective films have been removed. • Siemens base adapter with screws (supplied with the device version "support arm without extension components (flange on top)" and "pedestal/extension components (flange at bottom)").
  • Page 30 – Support arm or pedestal with mechanical VESA interface and the corresponding Siemens adapter set – Support arm or pedestal with mechanical interface for the Siemens base adapter (The type of mechanical interface differs depending on the type of support arm or pedestal.)
  • Page 31 Installing and connecting the device 3.3 Mounting the device 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 32: Support Arm And Extension Components (Round Tube)

    – Support arm with mechanical interface, which is appropriate for the flange of the flange mount, and Siemens flange mount (not included in product package). – Support arm with mechanical VESA interface, which is appropriate for the corresponding Siemens adapter set and the Siemens flange mount adapter (not included in product package).
  • Page 33 The following description shows an example of how to attach the PRO device to a support arm system using the optionally available Siemens flange mount ⑦. Mounting to a 48.3 mm round tube ⑧ that fits the opening of the PRO device is performed in a similar fashion.
  • Page 34 Otherwise, the device can become loose due to vibrations and drop. 4. If an adapter plate ⑨ for the Siemens flange mount is included with your support arm, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 35: Connecting The Device

    • Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch mains cables and data transmission cables during a thunderstorm. • Keep a sufficient distance from electric cables, distributors, and systems. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 36: Power Supply

    24 V CC sur le connecteur d'alimentation 24 V CC. 3.4.2 Power supply 3.4.2.1 Opening and closing the terminal compartment cover Requirements • The device is disconnected from the power supply. • Torx TX20 screwdriver SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 37 Opening the terminal compartment cover for the device version "pedestal and support arm device versions without extension components". Opening the terminal compartment cover for device version "support arm and extension components (round tube)". SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 38 The assignment of the interfaces is shown on the inside of the terminal compartment cover. 3. Run the connecting cables through the support arm or pedestal ① into the PRO device and connect them to the interfaces on the inside. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 39: Connecting The 24 V Dc Power Supply

    The 24 V DC power supply must be adapted to the input data of the device (see the section "Technical specifications (Page 79)"). Requirements • The device is installed. • The protective conductor is connected. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 40 The 24 V D C power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 41: Connecting The Protective Conductor

    Firmly attach the cable lug to the protective conductor connection on the device using the M4 thread (see part labeled). Connect the protective conductor to the protective conductor connection of the cabinet or the plant in which the device is installed. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 42: Connecting Peripheral Equipment

    You can use the integrated Ethernet interfaces (10/100/1000 Mbps) for communication and data exchange with automation devices, for example SIMATIC S7. You need a suitable software to use this functionality: STEP 7, WinCC, SIMATIC NET. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 43: Installing The Strain Relief

    The scope of delivery includes an accessories kit that contains the following strain relief for USB, DisplayPort cable and LAN RJ45 cable and the associated screws. Requirement • Strain relief • Screws • Screwdriver T10 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 44: Securing The Cables

    Procedure 1. Pass the cable tie around the respective strain relief bar and secure the cables as shown. ① Fastening with cable ties 2. Cut off the protruding ends of the cable ties. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 45: Commissioning The Device And Device Functions

    • Make sure that there are no conductive liquids on the touch screen during startup. • Do not touch the touch screen during startup. The device automatically calibrates the touch screen during startup. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 46: Switching The Device On/Off

    The operating safety of the device and the plant is at risk. Do not switch off the device during the entire installation process. Do not change the default values in the BIOS setup. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 47: Advanced Device Functions

    • Temperature monitoring (overtemperature or low temperature) • Monitoring of SSD with S.M.A.R.T. functionality • Watchdog (hardware or software reset of the computer) • Operating hours meter (information on total runtime) SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 48: Temperature Monitoring/Display

    A watchdog alarm is retained after a restart and is reset and logged by the DiagBase or DiagMonitor software. The watchdog configuration is retained in the process. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 49: Battery Monitoring

    A memory window with a maximum size of 512 KB can be displayed by means of PCI address register. The base address is initialized via the BIOS (see section "Input/output address areas (Page 109)"). A corresponding function is implemented there for using the NVRAM under SIMATIC software controller. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 50 Commissioning the device and device functions 4.3 Advanced device functions SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 51: Operating The Device

    IPC Driver and Tools Panel description - Panel Drivers and Tools (PDT) software The SIMATIC IPC PDT software installs the "IPC Configuration Center" software. The existing hardware components are automatically detected by the associated software. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 52: Operating A Device With Capacitive Multi-Touch Screen

    Incorrect operation of devices with a touch screen can occur. This can result in personal injury or property damage. Take the following precautions: • Configure the plant so that safety-related functions are not operated with the touch screen. • Switch off the device for cleaning and maintenance. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 53 – Surface contact with a diameter of > 3 cm, for example, resting the palm of the hand on the touch screen – As soon as the touch screen is no longer touched, input is possible again. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 54 Once the interference is over, the touch screen is no longer locked. Additional information A "touch pen system", which is suitable for both single-touch and multi-touch screens, is available on the Industry Mall (https://mall.industry.siemens.com) (6AV2181-8AV20-0AX0). SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 55: Expanding And Assigning Parameters To The Device

    Expanding and assigning parameters to the device Opening and closing the backplane cover Requirements • The device is disconnected from the power supply. • Torx TX20 screwdriver Opening the backplane cover SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 56 5. Tighten the M4x16 screws of the backplane cover in crosswise order using a maximum torque of 1.5 Nm. Check all screws again to ensure that the maximum torque of 1.5 Nm has not been exceeded. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 57: Installing The M.2 Module

    Installing the M.2 Module Introduction to the M.2 Module Siemens uses the M.2 Module to extend the Siemens IPC. You can use M.2 module produced by Siemens or other third-party suppliers. Our device provides one or several M.2 Key B interfaces and mounting positions.
  • Page 58 : Our device supports Key E and Key A+E module through the "M.2 Key E to Key B adapter" in the accessory (Page 18). : You can install 4G/5G SIM card through SIM card slot to connect to network. Requirement • The device is opened. • A T8 screwdriver SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 59 Module is completely seated on the slot. Secure the M.2 Module with the screw which is unscrewed in the first step. Note: Make sure the M.2 Module board is located between head and spacer of assembly screw. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 60 100 mm and no longer than 200 mm. Secure the additional interface-card in the position of the COM interface with screws. Procedure - Removing the M.2 Module Follow the above steps in reverse order to remove the M.2 Module. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 61: Installing And Removing M.2 Nvme/ Sata Ssd

    Procedure - removing the M.2 NVMe/SATA SSD To remove the M.2 NVMe/SATA SSD, carry out the steps for installing the M.2 NVMe/SATA SSD in the reverse order. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 63: Maintaining And Repairing The Device

    Maintaining and repairing the device Maintenance intervals To maintain high system availability, Siemens recommends you replace some of the PC components that subject to wear in according with the replacement intervals indicated in the table below. Component Replacement interval: CMOS backup battery...
  • Page 64 • A worn battery jeopardizes the function of the device. Change the battery in good time. • Replace the lithium battery only with batteries of the same type or a type recommended by SIEMENS. The article number for the lithium battery is A5E48370874. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 65 This can result in malfunctions and damage to the machine or plant. Make sure you take precautionary measures when you open the device. For more information, refer to the chapter "ESD Guideline (Page 83)" SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 66: Cleaning The Device Front

    You may possibly trigger unwanted actions of the device or controller that are liable to cause personal injury or damage to the machinery. Always switch off the device before you clean it. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 67 2. Moisten only the cleaning cloth, do not spray liquids directly onto the device. 3. Clean the enclosure surface with a damp cloth and make sure that no water enters the device. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 68: Installing And Removing Hardware

    – Rated voltage: 3 V DC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 115). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 69 – Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 115) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 70 Slide the battery out 45 degrees from the upper left, pull the battery out gently and insert a new battery. Note: The positive electrode (+) of the battery should be positioned toward the outside of the device. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 71: Replacing The Memory Module

    ESD directives on handling electrostatic sensitive components. Note Siemens strongly recommends that you use only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules. CAUTION • A memory module cab be installed only when the direction is correct. Make sure your insert the memory card in the correct direction.
  • Page 72 Unscrew the marked two screws on the power module, and then remove the cables of power module on the motherboard in order to remove the power module. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 73 T10 screwdriver on the motherboard. Press the retaining clips outward in the direction of the arrows to unlock the memory socket. Pull out the memory module from the socket. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 74 Unscrew the marked two screws on the back of the interface plate and remove the interface plate. Unscrew the marked two spring screws with a T8 screwdriver and other five screws with a T10 screwdriver on the motherboard. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 75: Reinstalling The Operating System

    • Windows 10 operating system is installed in your IPC. • You need to connect a mouse and a keyboard to your PC. • You also need the supplied USB stick to your PC. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 76 4. Click Accept to accept the license agreement. 5. Click Install to allow the computer to start the installation. The installation starts. 6. Click Yes to confirm the user account control question. 7. Click Finish. The chipset installation is completed. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 77 3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Click Yes to accept license agreement. 6. Click Next to confirm the Readme File Information and move on. The installation starts. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 78: Recycling And Disposal

    Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 79: Technical Specifications

    The following shows the approvals that may be available. For the device itself, it is certificated as shown on the product label and package label. ISO 9001 certificate The Siemens quality management system for all production processes (Development, Production, Sales and Service of Automation Products, -Systems and -Solutions) meets the requirements of ISO 9001:2015 This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 80 UL approval The following approvals are available for the device: • Underwriters Laboratories (UL) in accordance with Standard UL61010-1 and UL61010-2- 201, File E472609 • Canadian National Standard CAN/CSA No.61010-1-12 and CAN/CSA C22.2 No.61010-2- SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 81 Note 2: "○" indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence. 備考 3. “-”係指該項限用物質為排除項目。 Note 3:The "−" indicates that the restricted substance corresponds to the exemption. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 82: Directives And Declarations

    DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 78) ".
  • Page 83: Rohs Directive

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 84 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 85 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 86: Dimension Drawings

    Technical specifications 8.3 Dimension drawings Dimension drawings 8.3.1 Dimension drawing of 12" device Pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 87 Technical specifications 8.3 Dimension drawings Support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 88 Technical specifications 8.3 Dimension drawings Support arm and extension components ① With flange mount ② Without flange mount All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 89: Dimension Drawing Of 15" Device

    Technical specifications 8.3 Dimension drawings 8.3.2 Dimension drawing of 15" device Pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 90 Technical specifications 8.3 Dimension drawings Support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 91 Technical specifications 8.3 Dimension drawings Support arm and extension components ① With flange mount ② Without flange mount All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 92: Dimension Drawing Of 19" Device

    Technical specifications 8.3 Dimension drawings 8.3.3 Dimension drawing of 19" device Pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 93 Technical specifications 8.3 Dimension drawings Support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 94 Technical specifications 8.3 Dimension drawings Support arm and extension components ① Without flange mount ② With flange mount All dimensions in mm SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 95: Technical Data

    Burst: ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000- conducted interference on the 4-4; supply lines • Surge: ± 1kV line to line, ±2 kV line to earth in accordance with IEC 61000-4-5; SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 96 4G DDR4 SDRAM • 8G DDR4 SDRAM • 16G DDR4 SDRAM The max speed of memory is up to 3200 MT/s. The memory module supports IBECC function, and its default value in BIOS is "Disable". SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 97 3 × Gigabit Ethernet interface (three RJ45) electrically isolated, Wake on LAN and Remote Boot are supported: • X1P1: Marwell 88E1512 • X2P1: Marwell 88E1512 • X3P1: Marwell 88E1512 COM1 RS232/RS422/RS485 (optional), max. 115 Kbps, D-sub connector, 9-pin SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 98: Ambient Conditions

    : Equipment ambient temperature rating at 2000 m. : Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 99: Power Demand Of The Components

    Buffering upon power failure Hold-up time > 20 ms (after > 5 ms, DC_FAIL becomes active) Maximum continuous output power 30 W : The power specifications apply to the power supply component, not to the device. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 100: Power Supply For 15" And 19" Device

    Buffering upon power failure Hold-up time > 20 ms (after > 5 ms, DC_FAIL becomes active) Maximum continuous output power 80 W : The power specifications apply to the power supply component, not to the device. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 101: Hardware Descriptions

    Memory DDR4 SDRAM Memory expansion up to 16 GB with the following memory modules: • 4G DDR4 SDRAM • 8G DDR4 SDRAM • 16G DDR4 SDRAM Graphics Integrated graphics • Intel® UHD Graphics SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 102: External Interfaces

    Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output 8.5.2.2 DC in connector Short description +24V SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 103: Ethernet Port

    Ground ML_Lane 0- DP data 0- Output ML_Lane 1+ DP data 1+ Output Ground ML_Lane 1- DP data 1- Output ML_Lane 2+ DP data 2+ Output Ground ML_Lane 2- DP data 2- Output SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 104: Serial Interface

    Short description Meaning Transmit data - (O) for full-duplex mode Transmit data + (O) for full-duplex mode Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Signal ground SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 105: Internal Interfaces

    Internal • 1 × SIM card slot LVDS Internal • 1 × LVDS connector Backlight Internal • 1 × Backlight connector 8.5.3.1 USB 2.0 pin header Signal VBUS_USB1 VBUS_USB2 USB1_D- USB2_D- USB1_D+ USB2_D+ SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 106: M.2 Interface

    PERp1 UIM-RESET PERn1 CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B USB_D- W_DISABLE# USB_D+ WWAN_PWR_OFF_N 3.3V 3.3V SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 107 PETp1 PETn1 PERp1 PERn1 CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B USB_D- W_DISABLE# USB_D+ 3.3V 3.3V SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 108: Lvds Interface

    OTXN0- OTXP0+ OTXN1- OTXP1+ OTXN2- OTXP2+ OCLKN- OCLKP+ OTXN3- OTXP3+ ETXN0- ETXP0+ ETXN1- ETXP1+ ETXN2- ETXP2+ ECLKN- ECLKP+ ETXN3- ETXP3+ 8.5.3.4 Backlight interface Short description Short description P12V_BKLT P12V_BKLT P12V_BKLT F_BKLT_ON_R F_LBKLT_CTR F_LCD_OC_CON_N SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 109: System Resources

    SIO logic device 8 CR F2h Watchdog state register (Page 110) SIO logic device 7 CR FDh Battery status register (Page 110) For more information and reference code for accessing to Super IO, contact Siemens Technical support. 8.5.5.2 Watchdog control register...
  • Page 110: Watchdog Counter Register

    1: Watchdog Timer I issues time-out event. 3 to 0 Read/Write Not used for watchdog 8.5.5.5 Battery status register The status of the CMOS battery is monitored; the status (two-tier) can be read from the battery status register. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 111: Nvram Address Register

    The BIOS Setup program, or BIOS Setup for short, is located, together with the setup parameters, in a FLASH block on the motherboard. Change the setup parameters of the device in the BIOS Setup, e.g. system time or boot sequence. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 112: Bios Update

    8.6.2 BIOS update Check regularly if updates are available for download to your device. You can find additional information on the Internet at the following address: After-sales information system for SIMATIC PC/PG (http://www.siemens.com/asis). SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 113 If you have purchased a new BIOS update for your device, follow these steps to install the update: 1. Connect the device to the power supply. 2. Take the BIOS update you downloaded from the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/75852684)page and place it on the USB stick.
  • Page 114: Alarm, Error And System Messages

    Check the CMOS clock. Keyboard error • Field PG: Internal keyboard defective and no external keyboard connected • Other devices: Keyboard defective or not connected SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 115: Technical Support

    Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 116: Troubleshooting

    1. Open the BIOS Setup. on the PC 2. Set the time or date. Although the BIOS The backup battery is dead. Replace the backup battery. setting is OK, the time and data are still wrong SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 117: Notes On The Use Of Third-Party Modules

    If the error no longer occurs, the third-party module • Different pin assignment being used was the cause of the fault. Replace the thrid-party module with a Siemens module or contact the module supplier. If the device still crashes, contact your technical support team. •...
  • Page 118 Technical support A.3 Notes on the use of third-party modules SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 119: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical Eject CD/DVD isolation On/off switch, without electrical isolation SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 120: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Disposal information, observe the Laboratories local regulations. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 121: Interfaces

    DVI-D interface Line In LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 122 Markings and symbols B.5 Interfaces SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 123: List Of Abbreviations

    Disk Operating System DisplayPort Deutsche Gesellschaft zur Zertifizierung von Qualitätsmanagement mBH Data Set Ready Ready for operation Data Terminal Ready Data terminal is ready Digital Versatile Disk Components sensitive to electrostatic charge European standard SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 124 Optical Disk Drive Personal computer Peripheral Component High-speed expansion bus Interconnect PCIe Peripheral Component High-speed serial, differential full-duplex PtP Interconnect express interface with high data rate. Programming device POST Power On Self Test SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 125 Intel technology which provides a virtual, closed environment. VT-d Virtualization Technology for Enables the direct assignment of a device (e.g. Directed I/O network adapter) to a virtual device. Watchdog Program monitoring with error detection and alarming. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 126 List of abbreviations SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 127: Glossary

    Communauté Européene: The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the PCI or PCIe bus and the external interfaces. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 128 TVs to computers, DVD players and similar devices. Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 129 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 130 Intel Active Management Technology This technology permits diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 131 Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens AG issues a license key for each software that is protected by a license. License key USB flash drive The license key USB flash drive contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 132 Industrial Ethernet meets the requirements of industrial automation technology. Programmable controller The programmable controllers of the SIMATIC S7 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 133 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 134 Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 135: Index

    Interfaces Degree of protection, 95 RJ45 Ethernet, 103 DiagBase software, 48 USB 3.0, 102 DiagMonitor IT communication, 42 Temperature monitoring, 48 Diagnostics, 48 DiagBase software, 48 Directive Korea Certificate, 81 ESD Directive, 83 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 136 Removing, 23 PE conductor, 52 Pile au lithium, 69 Processor, 96 UKCAI, 82 Product label, 25 USB, 102, 105 PROFINET, 43 USB 3.0 Protection class, 95 Interface, 102 Protective measure Static electricity, 85 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...
  • Page 137 Index Ventilation slits, 29 Warranty, 19 Watchdog, 48 Monitoring function, 48 Monitoring times, 49 SIMATIC IPC277G PRO Operating Instructions, 02/2022, A5E51373692-AA...

Table of Contents