Technical Specifications
Section 5.2

Failsafe Relay Specifications

Maximum Switching Voltage
30 VDC
125 VDC
250 VAC
c
Inductive load R/L = 7 ms
d
Resistive load
Section 5.3

Operating Environment

The RUGGEDCOM RX1501 is rated to operate under the following environmental conditions.
IMPORTANT!
Temperature limits for select line modules may differ from that which can be withstood by the
RUGGEDCOM RX1501. Make sure the selected modules are rated for the expected environmental
conditions before deployment. For more information, refer to the RUGGEDCOM RX1501 Series Modules
Catalog.
Ambient Operating Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
e
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with Underwriter Laboratories (UL) listed devices.
f
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
g
Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings.
h
Non-condensing.
Section 5.4

Mechanical Specifications

Weight
Ingress Protection
Enclosure
40
Rated Switching Current
efg
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
h
5% to 95%
12192 m (40000 ft)
Approximately 4.7 kg (10.3 lb)
IP30
Aluminum
5 A
c
d
0.1 A
, 0.15 A
6.25 A
RUGGEDCOM RX1501
Installation Guide
Isolation
2800 VDC for 1 minute
between coil and contacts
Failsafe Relay Specifications