LG GC-W061BTH.CTICJHK Service Manual page 21

Table of Contents

Advertisement

MICOM FUNCTION AND CIRCUIT DIAGRAM
6-2-6. Switch Input Circuit
Input Circuit is to sense a TEST-S/W signal for refrigerator inspection.
6-2-7. Temperature Sensing Circuit
This circuit consists of top/bottom sensor, top EVA/bottom EVA sensor for controlling top/bottom parts' storage/maturing
temperature, and an exterior temperature sensor. Each sensor's SHORT and OPEN condition is as followed.
Sensor
Exterior Sensor
POINT A Voltage
Top Sensor
POINT B Voltage
Bottom Sensor
POINT E Voltage
Top EVA Sensor
POINT C Voltage
Bottom EVA Sensor
POINT D Voltage
P11
Check Point
Normal (-30
R18
20
℃ ℃ ~50 ℃ ℃ )
0.5 V~4.5 V
- 21 -
SHORT
OPEN
0 V
5 V