1
A
Recovery flowchart (2-1)...Changing the VOL YNOFS3/4/1 setting voltage
[From the Main flowchart (2)]
RST MASK 16 (Green 1023+)
Set VOL YNOFS1 to the tentative setting value. / [VY1 ***]
B
Set VOL YNOFS3 to the current setting value +4. / [VY3 ***]
Set VOL YNOFS4 to the current setting value +4. / [VY4 ***]
Current VOL YNOFS3 setting value > 137?
C
Is there erroneous discharge (abnormal dead cell)?
Display RST MASK 15 (Red 1023+). / [MKS S65]
D
Is there erroneous discharge (abnormal dead cell)?
Display RST MASK 22 (Cyan 3SF). / [MKS S72]
Set VOL YNOFS3 to the current setting value +47. / [VY3 ***]
E
Set VOL YNOFS4 to the current setting value +47. / [VY4 ***]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
F
136
1
2
No
No
No
No
B
PDP-5010FD
2
3
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Yes
Yes
To the Recovery flowchart (2-2)
From the Recovery flowchart (2-2)
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
3
4
4