Siemens DF481100F Information For Use page 51

Table of Contents

Advertisement

Fault
Appliance door opens
too wide when activ-
ated.
Appliance door opens
accidently.
E:2060 lights up.
E:2130 lights up.
E:3000 lights up.
E:3100 lights up.
E:3200 or indicator
for water supply lights
up.
1
Depending on the appliance specifications
Cause and troubleshooting
Door is not correctly adjusted.
Adjust the appliance door as described in the in-
stallation instructions.
Automatic door opening activated accidently.
To prevent the appliance door opening accidentally,
activate the childproof lock.
Appliance has detected calcified heating element.
Descale the appliance.
1.
Operate the appliance with the water softening sys-
2.
tem → Page 31.
Intake opening of Zeolith container is covered by
items of tableware.
Re-arrange the tableware in the appliance so the In-
take opening of the Zeolith container → Page 15 is
no longer obstructed.
Water protection system is activated.
Turn off the water tap.
1.
Call Customer Service → Page 66.
2.
Water protection system is activated.
Turn off the water tap.
1.
Call Customer Service → Page 66.
2.
Supply hose is kinked.
Install the supply hose without kinks.
Water tap is turned off.
Turn on the water tap.
Water tap is jammed or furred up.
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
The filters in the water connection of the supply or
AquaStop hose are blocked.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
1
Troubleshooting en
51