Inspection; Visual Inspections; Checking The Oil Level Of The Planetary Gearbox - Bosch Rexroth ROTATRAC eGFT 8000 10 Series Manual

Electromechanical drives for mobile applications
Table of Contents

Advertisement

10.2 Inspection

Perform visual controls and inspections as specified in chapter
10.3 "Maintenance schedule planetary gearbox".

10.2.1 Visual inspections

Check for leakage in accordance with the intervals specified in the maintenance
schedule in chapter 10.3 "Maintenance schedule planetary gearbox". Signs of
leakage include more and more frequent moisture areas on the partition seams or
even oil drops.

10.2.2 Checking the oil level of the planetary gearbox

Danger of burns!
The planetary gearbox heats up to max. 90 °C in the oil sump during operation so
that it may cause burns!
Let the planetary gearbox cool down to approx. 50°C before touching it.
To protect yourself from burns, wear appropriate protective clothing such as
heat-resistant safety gloves.
Always wear protective goggles.
Risk of injury!
Solid particles, such as metal particles or metal abrasion, which are in the
lubricating oil or on the screw plug can cause injury!
Wear appropriate protective clothing.
Risk of damaging the planetary gearbox!
If the oil level is too high or too low, damage or failure may result to the planetary
gearbox. Too high an oil level can be a sign of foreign fluid penetrating or failure of
the oil pump required in the oil cooling system. If the oil level is too low, this may
indicate an oil leak!
Check for any leaks if the oil level is too low.
Determine the cause before refilling. Contact the Rexroth Service located in your
area, for the address refer to appendix
A "Address directory" in the material number-specific operating instructions.
Check the oil level of the planetary gearbox in accordance with the intervals
specified in the maintenance schedule in chapter 10.3 "Maintenance schedule
planetary gearbox".
Refer to the dimensioned drawing of the planetary gearbox for information about
the position of the oil filler opening, the circulating oil lubrication (oil cooling),
the oil level control system and the oil drain.