Figure 5-7 Owner settings
Exception Description
If the factory settings are restored without unbinding the charger from the PV
plant, the charger will go offline in the management system after power-on and
power-off or network disconnection recovery. In this case, you need to unbind the
charger from the plant and then bind it again to restore the communication.
Step 1 Power off the charger.
Step 2 On the management system, click Unbind. The charger is now disconnected from
the management system, and a message is displayed indicating that the password
fails to be reset. Ignore the message and click Confirm again.
Issue 02 (2023-01-13)
Copyright © Huawei Technologies Co., Ltd.
5 Maintenance
78