SELF DIAGNOSIS FUNCTION
Retry Limitation by Remote/Power Key
Smart Core
Red LED blinking
count
2x
3x
4x
5x
6x
7x
8x
*1) If STDWN_OFFON_CNT <= STDWN_RTRY_LIMIT, and STDWN_OFFON_CNT_MAIN_POWER <= STDWN_RTRY_LIMIT_MAINPOWR, you can turn the set on
by a remote/power key. At this time, if the error occurs again, the STDWN_OFFON_CNT is incremented by 1.
*2) When the main micro operates normally for STDWN_OFFON_CLR = 60 minutes, STDWN_OFFON_CNT and STDWN_OFFON_CNT_MAIN_POWER are cleared.
SAFETY NOTES
Error Name
Retry Permission Times
MAIN_POWER
STDWN_RTRY_LIMIT_MAINPOWR = 1
DC_ALERT (5V)
STDWN_RTRY_LIMIT = 2
AUD_ERR
STDWN_RTRY_LIMIT = 2
LD_ERR
STDWN_RTRY_LIMIT = 2
BCM_ERR
STDWN_RTRY_LIMIT = 2
P_ID_ERR
STDWN_RTRY_LIMIT = 2
BACKLIGHT
STDWN_RTRY_LIMIT = 2
TEMP_ERR
STDWN_RTRY_LIMIT = 2
4KBE_ERR
STDWN_RTRY_LIMIT = 2
SELF DIAGNOSIS FUNCTION
Note
*1
TROUBLESHOOTING
SERVICE ADJUSTMENT
Number of off/on action for MAIN_POWER
shutdown is recorded to
STDWN_OFFON_CNT_MAIN_POWER.
Number of off/on action during the
error shutdown is recorded to
STDWN_OFFON_CNT.
DIAGRAM
HANDLING GUIDE