RED LED
RECALL BUTTON
Figure 32. 103217-03 Integrated Control
(Automatic Hot Surface Ignition System)
W
C
Push Button
Diagnostic LED
Error Recall
Figure 33. 107163-01 Integrated Control
Page 24 of 36
BLOWER OFF DELAY
PARK
R
G
Y
Heating Blower Off
Delay Selector Switch
1/4" Quick Connect Terminal Designations
120V HUM
LINE
XFMR
CIRC
EAC
HUM24
NEUTRALS (5)
3/16" Quick Connect Terminal Designations
COOL
HEAT
FAN
PARK (3)
FS
24V COM
Table 9. Terminal Designations
(Applicable to 103217-03 and 107163-01 Controls)
Issue 2209
Power for Humidifier (120VAC)
Incoming Power Line (120VAC)
Transformer Primary (120VAC)
Indoor Blower Motor (120VAC)
Electronic Air Cleaner (120VAC)
Power For Humidifier (24VAC)
Neutral
Cool Speed From Indoor Blower Motor
(24VAC)
Heat Speed From Indoor Blower Motor
(24VAC)
Continuous Fan Speed From Indoor
Blower Motor (24VAC)
Terminals For Unused Motor Speed
Taps
Flame Sensor Electrode (120VAC)
Common (24VAC)
507330-03G / 31-5000662