Wiring Diagram - Bosch 15 SEER2 Series Installation Instructions Manual

Inverter ducted packaged heat pump
Table of Contents

Advertisement

13.14 Wiring Diagram

W2 V2 U2
CN32
OUTDOOR FAN MOTOR
IPM
G R A Y
W
W
B R O W N
V
V
U
B L A C K
U
U
W
PFC
COMP.
RED
CN1
CN18
L1
B L A C K
CN2
L2
240V
Y E L L O W
R E D
208V
24V
B L A C K
Y E L L O W
COM
NOTE:If the input voltage
TRANSFORMER
is 208V,take the red wire
to 208V terminal.
B R O W N
P U R P L E
Y E L L O W
R E D
B L U E
O R A N G E
B L A C K
R E D
I N D O O R F A N M O T O R
XT2
R E D
B L A C K
R E D
B L A C K
Y/G
RED
BLACK
NOTE:When using two-stage
XT1
L1 L2
thermostat,remove this wire.
Indoor Board LED Code
Normal
ON
Power in
1
Dehumidification mode active
Use copper conductors only
Evap freeze protection active
2
SPEED TAPS
1 2 3 4 5
3
Anti-cold air function active
1
LOW
2
4
MEDIUM LOW
Temperature sensor fault(T1)
3
MEDIUM
5
Temperature sensor fault(T2)
4
MEDIUM HIGH
5
6
N G L C
Communication error
HIGH
Figure 57
Outdoor Board LED Code
ON
Compressor running.
fl ashing
2s ON then 2s OFF, Compressor is standby.
fl ashing
Flashing then 3s OFF. Compressor error will show on digital display tube.
fl ashing
Flashing quickly 400ms/cycle. Compressor chip communication error.
Table 38
Bosch 15 SEER2 Inverter Ducted Packaged Heat Pump - BTC 761701319 A (12.2022)
S D
1 P
CN25
CN10
SW3
SW2
SW1
CN21
CHECK FORCE
ON
ON
CN11
1
2
3
4
1
2
SW4 SW5
ON
CN14
1
2
SW6
CN16
BLACK
O U T D O O R
WHITE
M A I N B O A R D
CN7
BLUE
CN20
CN13
RECTIFIER
CN9
CN12
CN8
GND1
GND2
CN17
CN3
C N 3 5
SW6
L E D 4
ON
1
2
3
4
G R E E N
C N 3 7
C N 3 3
INDOOR
MAIN BOARD
C N 1 3
C N 3 0
C N 8
C N 1 2
NOTE:
C
R
Y1 Y2
B
Dh W2 W1
G
T2 T1
To thermostat
*The factory Default (Indoor unit)
SW6-4 ON
ON
2 2
1
1
2
ON
3 2
2 1
SW6-1,2
1
2
Speed Taps
ON
2 1
(Indoor unit)
4 3
*
1
2
ON
3 2
5 4
1
2
H MH M
ON
HEAT:ANTI-COLD AIR FAN DELAY
SW6-3
OFF
HEAT:FAN DELAY START
ON
AUTO FAN CONTROL
SW6-4
TWO STAGE FAN CONTROL
OFF
WARNING
ELECTRIC HAZARD 380V VOLTS DC
WAIT 3 MINUTES AFTER DISCONNECTING POWER,THEN
HPS
VERIFY DC VOLTAGE LESS THAN 42 VDC AT INVERTER
TEST POINTS P-N. COMPONENTS MAY STORE A
DANGEROUS ELECTRICAL POTENTIAL OF 380 VOLTS DC.
FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PERSONAL INJURY OR DEATH.
*The factory Default (Outdoor unit)
T5
ON
ON
ON
ON
ON
PT
*
*
2
1
2
3
4
OFF
1
OFF
1
2
SW5
SW6
SW4
T3
T4
ON
Must be set at ON position. For IDP
T3L
SW4-1
OFF
For IDS
Th
ON
Unused
SW4-2
OFF
Must be set at OFF position
EEV
Adaptive capacity output disable
ON
SW4-3
OFF
Adaptive capacity output enable
Accelerated cooling/heating
ON
SW4-4
Normally cooling/heating
OFF
RV
CCH
ON
Operating time is reduced by 10%
SW5-1
*
Enter defrost
OFF
Normal
SW5-2
ON
Defrosting extended for 60 seconds
*
Quit defrost OFF
Normal
ON
ON
For 24K model
OFF
1 2
ON
ON
For 36K model
OFF
1 2
SW6
ON
ON
Set capacity
For 48K model
OFF
1 2
(Outdoor unit)
ON
ON
For 60K model
OFF
1 2
SW3
Wifi setting (Reserve)
PRESS
PRE
S
S
Check the system parameters
CHECK
1s 1s
PRESS
Test mode (Not used)
6s
Forced cooling/heating
PRESS
FORCE
1s
(Charge mode)
PRESS
Forced defrosting
6s
TO HEATER KIT
CODE
Description
HPS
High pressure switch
T5
Comp. discharge temp. sensor
: Factory optional
PT
Pressure transducer
: Field installed
T3
Condensor temp. sensor
T4
Ambient temp. sensor
ON
ON
T3L
Condensor outlet temp. sensor
*
1
2
3
4
OFF
Th
Comp. return temp. sensor
SW6
TF
Control board module temperature
T1
Return air temp. sensor
*
SW6-4 OFF
T2
Indoor coil temp. sensor
EEV
Electric expansive valve
1
2
1
RV
Reversing valve
1
3
CCH
Crankcase heater
COMP.
Compressor
4
2
TEMP.
Temperature
5
3
Date
Factory code
L H MH M
L
16027700002615
Nov. 26th,2022
*
*
Note: This manual is for reference only, actual
product may vary.
Installation Instructions
CODE
Fault description
C3
The coil sensor is seated fault in cooling(T3)
E4
Temperature sensor fault(T3,T4,T5,Th,T3L)
E5
High/Low voltage protection
E6
DC fan motor fault
E7
Compressor discharge sensor is seated fault (T5)
E9
EEPROM fault
F1
High pressure switch(HPS) fault
H0
Communication fault in main control chip
H5
5 times (P2) protection in 100 minutes, lockup
H8
Pressure transducer fault (PT)
ON
L0-L9
The IPM module protection(only for analysis)
P0
High module temperature protection(TF)
OFF
P1
High pressure protection (HPS)
P2
Low pressure protection in cooling or heating (PT)
*
P3
Compressor over current protection
P4
High T5 protection
P5
Condensor coil temperature protection in cooling (T3)
P6
IPM module protection
*
P8
DC fan motor hurricane/typhoon protection
PH
Low discharge superheat protection
*
AtL
Ambient Temperature Limited T4 (heat pump)
PC
Evaporator freezing protection
*
E1
Communication error
CODE
Description
Forced operation mode
L
Running indication under T3 limited condition
D
Running indication under T5 limited condition
P
Compression ratio protection limit
F
Running indication under TF limited condition
C
Running indication under current limited condition
U
Running indication under low voltage limited condition
A
Running indication under return oil model
dF
Running indication under defrost model
Number Point check content
0
Outdoor unit capacity,example:H3=Heat pump 3 ton
1
Outdoor unit mode:0-standby,2-cooling,3-heating
2
Outdoor unit set compressor speed(Hz)
3
T3:outdoor coil temp.(°F)
4
T4:outdoor ambient temp.(°F)
5
T5:compressor discharge temp.(°F)
6
Th:compressor suction temp.(°F)
7
T3L:(liquid line temp.)(°F)
8
TF:module temp.(°F)
9
Pe:evaporating pressure(PSI)
10
Pc:condensing pressure(PSI)
11
Tes:target evaporating temp.(only for cooling mode)(
12
Te:evaporating temp.
(
°F
)
Tcs:target condensing temp(only for heating mode)(
13
14
Tc:condensing temp.(°F)
Target of the compressor discharge superheat
15
(heating mode only):Target value (°F)
16
Compressor discharge superheat
Opening of EEV:Actual value
17
18
Outdoor fan speed
19
Compressor current(A)
20
Power AC voltage Input(V)
21
DC voltage(V)
22
Continuous running time of the compressor(min)
23
Last fault code
24
Software version
25
T1:Return air temp.(°F)
Revision
26
T2:Indoor coil temp.(°F)
C
Indoor fan speed
27
Ts:Assume thermostat set point temp.(°F)
28
29
Remark"--"
°F
)
°F
)
°F
(
)
| 43