Duty Cycle - Panasonic YD-200KR Operating Instructions Manual

Thyristor controlled mig/mag arc weldingpower source
Table of Contents

Advertisement

DUTY CYCLE

100
50
YD-200KR
(Service Range)
(%)
0
50 100
100
50
(%)
0
60 100
Welding Current (A)
100
50
(%)
0
60 100
A rated duty cycle 50% means to use the rated welding current for 5 minutes out of 10 minutes
and suspend operation for remaining 5 minutes.
If the rated duty cycle is exceeded, a temperature increase value tops the maximum allowable
temperature of the equipment and the equipment may be deteriorated or burnt out.
The figure above shows the relations between the welding current and duty cycle for the
YD-200KR2/-350KR2/-500KR2 welding current value and use the equipment within that range.
When using in combination with other device such as welding torch, etc. use at the lowest
duty cycle reactor of each device.
60%(155A or less)
60%
Rating
200
300
Welding Current (A)
60%(248A or less)
60%
Rating
YD-350KR
(Service Range)
200
300 350 400
60%(387A or less)
YD-500KR
(Service Range)
300
200
400
Welding Current (A)
60%
Rating
500
17