Board - Sony BETACAM SX DNV-5 Maintenance Manual

Hide thumbs Also See for BETACAM SX DNV-5:
Table of Contents

Advertisement

1-9-2. CNB-1 Board
SL101
SL1
A
CNB-1 A Side
Slit Land
Ref. No.
SL1 Destination select
n
Set SL1 according to the destination during board replacement.
SL101 Power supply select
Slit short : Supplies electric power from the battery to the unit automatically when the external power
supply voltage is lower than the battery voltage.
Slit open : Supplies electric power from the external power supply to the unit irrespective of the voltage
level of the external power supply when the electric power is supplied from the external power
supply.
Power supply select
Slit
SL101
SHORT
OPEN
(Factory setting)
DNV-5
1
2
3
4
B
C
Description
OPEN : For except Japan
SHORT : For Japan
Input voltage
EXT DC > BATT
EXT DC
EXT DC
1-9. Switch/Slit Land Settings on the Boards
Factory setting
OPEN (for except Japan)
SHORT (for Japan)
Input voltage
EXT DC < BATT
BATT
EXT DC
1-9-2. CNB-1 Board
1-19