Download Print this page

Toshiba RKP007Z User Manual page 2

Remote keypad option

Advertisement

Remote Keypad Option
RKP007Z user's manual
1. Make sure that this instruction manual is delivered to the end user of Remote Keypad.
2. Read this manual before installing or operating the Remote Keypad. Keep it in a safe place for reference.
3. All information contained in this manual is subject to change without notice. Please contact
your Toshiba distributor to confirm the latest information.
Safety Precautions
On the inverter and in its instruction manual, important information is contained for preventing
injuries to users, damages to assets, and for proper use of the device.
Read the instruction manual attached to the inverter to understand the safety
precautions, the symbols and indications completely.
Please adhere to the contents of these manuals at all times.
Please refer to the inverter's instruction manual for detail functions and operation of this unit.
 Limitation of use
 Never use the Remote Keypad with any device other than applicable TOSVERT series
inverters. Doing so will cause an accident.
Prohibition
 Handling in general / Installation
 Never disassemble, modify or repair the Remote Keypad.
The disassembling will cause electric shocks, fire or injuries.
Never
Please call your Toshiba distributor for repairs.
Disassemble
 Do not put or insert foreign objects such as waste cable, bars or wires into the
Remote Keypad. It will lead to electric shocks or fire.
 Do not splash water over the Remote Keypad. It will lead to electric shocks or fire.
 Do not install or operate the Remote Keypad if it is damaged or any part of it is missing.
Prohibition
Operating the defective product can lead to electric shocks or fire.
Please call your Toshiba distributor for repairs.
 Turn off the power immediately in case of any abnormalities such as smoke,
smell, blind display or abnormal noise. Neglect of these conditions can lead to fire.
Please call your Toshiba distributor for repairs.
 Use an emergency stop device and an additional safety device with your system
Mandatory
to prevent a serious accident due to the Remote Keypad malfunctions.
action
Usage without any emergency stop device and any additional safety device may
cause an accident or injury.
 Do not install the Remote Keypad in any place subject to vibrations or it may fall.
This will lead to the product falling and causing injury.
Prohibition
 Do not apply a dropping shock or other physical shocks.
Otherwise, damage or malfunction will result.
 Do not connect a LAN or telephone modular cable to the Remote Keypad.
Doing so will cause a malfunction or accident.
Prohibition
 Do not pull on the cable and the connector. It can cause damage or malfunction.
 Operate under the environmental conditions prescribed in this instruction manual.
Operations under any other conditions can result in malfunction.
 Use the Toshiba-specified cable for connecting the Remote Keypad.
Mandatory
The use of any other cable can cause a malfunction.
action
 Disposal
 If you dispose of the Remote Keypad, have it done by a specialist in industrial
waste disposal*.
Improper disposal can cause to produce noxious gases and result in accident.
(*) Persons who specialize in the processing of waste and known as "Industrial
Waste Product Collectors and Transporters" or "Industrial Waste Disposal
Mandatory
Persons." If the collection, transport and disposal of industrial waste is done by
action
someone who is not licensed for that job, it is a punishable violation of the law
(Laws in regard to cleaning and processing of waste materials).
Accessories
Remote Keypad is shipped together with the following accessories. On opening the packing box,
check to see if the following accessories are contained or not.
(1) User's manual (E6581592) ...................................................1 copy
(2) Key cover ..............................................................................1 pcs.
(3) Mounting screws (M3 x 10mm) .............................................4 pcs.
(M3 screw tightening torque: 0.6 Nm)
 Optional parts list
These are not provided with Remote Keypad. They should be purchased separately.
Interconnection cable : CAB0071 (1m), CAB0073 (3m), CAB0075 (5m)
* Please connect the connector of the extended back of panel, between the communication
connector of the inverter by this cable.
Outline drawing
Outline drawing
50
RUN
%
PRG
MON
Hz
MODE
LOC
REM
ENT
FWD
STOP
RUN
REV
RESE
Operation key
RUN: Operation (*1)
[RUN], [STOP / RESET]
Case of the trip, it is reset by STOP/RESET key pressed twice.
[
], [
]
Up or down for setting parameters.
[MODE], [ENT]
Same as "MODE key" and "ENT key" of the inverter.
The function is based on inverter series. Refer to the operation manual of
[FWD / REV],
the inverter for the contents and setup. FWD/REV is used forward
run/revers run selection etc., LOC/REM is used for
[LOC / REM]
local/remote change etc..
(*1): Parameter setup is required. It is effective when a panel (extended panel) is selected.
Notice
WARNING
WARNING
CAUTION
NOTICE
CAUTION
Manual
(17.5)
7.7
15.1
Unit: mm
Box color: RAL 7016
Panel color: PANTONE 426C
Approx. weight: 39g
*Dot Line shows a key
cover location
Function
STOP/RESET: Stop (*1)
Mounting
(50)
8
34
17.5
2.3
29.4
Before contacting your Toshiba distributor
■Trip information
Error code
Name
Operation panel
a-17
A-17
key alarm
Abnormal
coMe
COM.E
communication
cpUe
CPU.E
CPU fault
raMe
RAM.E
RAM fault
roMe
ROM.E
ROM fault
Product Specification
Item
Type form
RKP007Z
Applicable model
VF-FS1, VF-nC3, VF-S15, VF-AS3 *
Protocol: Modbus RTU
Communication
Baud rate: 9600, 19200, 38400 bps (Automatic detection)
configuration
Parity: Even, Odd, None (Automatic detection)
Indoor location (free from direct sunlight, corrosive gas, explosive gas,
Environment
combustible gas, oil mist, dust, metal powder, grinding fluid, etc.)
Ambient temperature
-10 to 60 °C
Storage temperature
-25 to 70 °C
20 to 93% (free from condensation and vapor)
Relative Humidity
Altitude
3000 m or less
2
5.9 m/s
(0.6G) or less (10 to 55 Hz) (IEC60068-2-6)
Vibration
Protection (IP code)
IP54 (under the condition to be installed on flat panel) *
*1: Please check the newest application model with the operation manual of each the inverter.
*2: When you apply to VF-FS1, please set up f829=1 (Modbus RTU).
*3: You should confirm it on your final product, because it depends on the coarseness or the flatness of your panel.
Warranty
■Warranty period
This product's warranty period is 12 months after the purchase, or 18 months from the
manufacture, whichever precedes the other.
The warranty period of repaired products will not exceed the warranty period before the repair
takes place.
■Scope of warranty
If a product failure is found during the warranty period due to our negligence, please return the
product to Toshiba distributor of purchase, for a replacement or repair of the defective
component.
The warranty shall only cover the purchased or delivered product itself.
The following circumstances will incur paid service even before the warranty period expires.
- Product replacement or repair when the product is not returned.
- Product failure or damage due to misuse, inappropriate repair or modification of the product.
- Product failure or damage for reasons such as but not limited to a fall after purchase, an
accident during transport, or handling (e.g. smoking) during transport.
- Product failure or damage by natural disasters or unforeseeable external causes such as but
not limited to fire, salt exposure, gas exposure, earthquakes, storms, floods, lightning and
abnormal voltage.
- Product failure or damage by use under inappropriate circumstances, environments or use not
suggested in the product catalog or instruction manual, or use not complying with the original
use intended for the product.
- Product failure or damage by the lack of proper maintenance or replacement of expiring parts
suggested in the instruction manual.
- In case the product is embedded in your equipment, product failure or damage by causes
irrelevant to the product, such as the design of your equipment and software.
- In case the product is embedded in your equipment, product failure that could have been
avoided if your equipment had featured a safety device in compliance with the law that
governs your equipment, or any feature or structure that is considered the norm by the
industry standard.
- Any product failure or damage by accidents that were unforeseeable with the technological
standard at shipment.
■Warranty exemptions
Irrespective of the warranty period, the warranty shall not cover the following conditions.
- Compensation for any damage not attributed to our negligence.
- Compensation for any loss of business opportunity or income caused by failure of the product.
- All liabilities and compensations for any damage, secondary damage, accidents, damage to
any entity that is not the product and damage to any other operations that arise from special
circumstances, that we may or may not foresee.
- Any compensations for the results of your product replacement, readjustment of the local
equipment after replacement, launch test, inspections, or any other operations.
■Service after the stop production
Please ask Toshiba distributor of purchase about the stop of production and repair work for
each product.
580, Horikawa-cho, Saiwai-ku, Kawasaki, Kanagawa 212-0013, Japan
TEL: +81-44-520-0828 / FAX: +81-44-520-0508
https://www.toshiba-tips.co.jp/en/contact/eu.html
E6581592⑦
4-Φ4.0
Φ28
(Front side view)
Unit: mm
Applicable board thickness: less than 3mm
Solution
The RUN or STOP key is held down for more
than 20 seconds.
Check the operation panel.
Check the connection of the inverter's serial
communication cable and communication
parameters (
f800
~) of inverter.
This indication will automatically cancel itself.
If abnormality is not found after checking and
resetting Remote Keypad, it needs to be
repaired.
If the same indication appears after resetting
Remote Keypad, it needs to be repaired.
Specification
1,
2
*
3
©Toshiba Schneider Inverter Corporation 2009

Advertisement

loading