Bosch D7212GV2 Operation And Installation Manual

Bosch D7212GV2 Operation And Installation Manual

Hide thumbs Also See for D7212GV2:
Table of Contents

Advertisement

Quick Links

D7212GV2
Operation and Installation Guide
EN
Control Panel

Advertisement

Table of Contents
loading

Summary of Contents for Bosch D7212GV2

  • Page 1 D7212GV2 Operation and Installation Guide Control Panel...
  • Page 2 User repairs must not be made, and doing so Commercial Fire (UL864). will void the user’s warranty. If the D7212GV2 Control Panel causes harm to the Burglary telephone network, the telephone company attempts to notify you in advance. If advance notice is not...
  • Page 3: Table Of Contents

    D7212GV2 | Operation and Installation Guide | Contents Testing the System ........... 18 Contents Power Supply..........19 Primary Power Terminals 1 and 2 ....19 Introduction............6 5.1.1 Primary (AC) Power Circuit ......19 Lightning Strikes ..........7 5.1.2 Installing the Transformer....... 19 Effects..............
  • Page 4 D7212GV2 | Operation and Installation Guide | 1.0 Introduction 9.1.5 D7212GV2 Responses to Missing 12.4.2 Address Settings ..........49 Point Conditions ..........32 12.4.3 Supervision............49 D8125, D8127 and D9127 POPIT Modules .32 12.5 SDI Address 88..........49 Installing the D8125 POPEX Module ...34 12.5.1 D9133DC Direct Connect Programming...
  • Page 5 D7212GV2 | Operation and Installation Guide | Figures Figures Tables Figure 1: System Configuration ......... 8 Table 1: Related Documentation......6 Figure 2: Enclosure Mounting........14 Table 2: Control Panel Capabilities ......8 Figure 3: Ground Fault Detection......15 Table 3: Compatible Accessories ......10 Figure 4: Reset Pin.............16...
  • Page 6: Introduction

    D9412GV2, D7412GV2, D9412G, D7412G, D7212G, D9412, D9112, D9112B1, D7412, D7212, or D7212B1 control panels. Throughout this guide, the words “control panel” refer to the D7212GV2 Control Panel. Table 2 on page 8 provides an overview of the capabilities of the D7212GV2.
  • Page 7: Lightning Strikes

    D7212GV2 | Operation and Installation Guide | 2.0 Lightning Strikes 2.0 Lightning Strikes The control panel is designed to significantly reduces electromagnetic interference and malfunction generally caused by lightning. Effects Any electronic system can be struck directly by lightning or be adversely affected by a lightning strike near the system.
  • Page 8: Overview

    D7212GV2 | Operation and Installation Guide | 3.0 Overview 3.0 Overview Configuration and Parts Figure 1: System Configuration Each D8128D OctoPOPIT combines D8129 OctoRelay provides alarm eight POPIT points in one module. and auxilliary relay output. (Other functions available.) Control...
  • Page 9: Parts List

    D7212GV2 | Operation and Installation Guide | 3.0 Overview 3.1.1 Parts List 3.1.2 Parts Available by Separate Order The D7212GV2 Control Panel is shipped pre- Order the following components separately to assembled from the factory with the following parts: complete a basic 8-point installation.
  • Page 10: Accessories

    D7212GV2 | Operation and Installation Guide | 3.0 Overview Accessories Refer to the Bosch Security Systems product catalog for additional information. Table 3: Compatible Accessories Model Title Model Title D122/D122L Dual Battery Harness D1256 Fire Command Center D125B Powered Loop Interface Module...
  • Page 11: Features In The D7212Gv2

    3.3.3 Super Capacitor account. The D7212GV2 has a capacitor called Super Cap. This Area options include exit tone and delay, separate fire component preserves the parameters stored in the and burglary outputs, and multiple opening and closing control panel’s RAM chip when the lithium battery is...
  • Page 12: Keypads

    D7212GV2 | Operation and Installation Guide | 3.0 Overview The system can route groups of Event Reports to four 3.3.11 Event Log different destinations. Each report group can be The system stores 500 to 1000 events and event programmed to send reports to one or more modifiers from all areas in its event log.
  • Page 13: Other Features

    D7212GV2 | Operation and Installation Guide | 3.0 Overview 3.3.15 Other Features The D7212GV2 Control Panel has many programmable features. Some of the features are listed below. Complete details on all features are in the D7212GV2 Program Entry Guide (P/N: F01U003804).
  • Page 14: Installation

    D7212GV2 | Operation and Installation Guide | 4.0 Installation Enclosure Options 4.0 Installation Mount the control panel assembly in any of the Bosch Security Systems enclosures listed: Installation Preparation • D8103 Universal Enclosure (tan) This section contains a general installation procedure •...
  • Page 15: Installing The Control Panel

    D7212GV2 | Operation and Installation Guide | 4.0 Installation • If a ground fault condition occurs, the keypads Installing the Control Panel display SERVC GND FAULT and the control panel 1. Place the control panel over the inside back of the...
  • Page 16: Enabling Ground Fault Detection

    D7212GV2 | Operation and Installation Guide | 4.0 Installation If the reset pin is placed in the disable position when 4.5.3 Enabling Ground Fault Detection all areas are armed, there must be an entry in the To configure the D7212GV2 Control Panel to enable Answer Armed program item.
  • Page 17: Completing The Installation

    D7212GV2 | Operation and Installation Guide | 4.0 Installation 4.6.3 Installing Modules and Relays Completing the Installation Power down the unit by unplugging the If not already complete, make the earth ground transformer and disconnecting the battery. connection to Terminal 10 and lock the reset pin in the closed position.
  • Page 18: Programming The Control Panel

    D7212GV2 | Operation and Installation Guide | 4.0 Installation Programming the Control Panel If the control panel is not already programmed, review the D9412GV2/D7412GV2 Program Entry Guide. Ensure that all accessory modules for desired features are available for installation. Place the reset pin in the locked position to copy or send information to and from the control panel.
  • Page 19: Power Supply

    D7212GV2 | Operation and Installation Guide | 5.0 Power Supply 4. Plug the transformer into an unswitched, 120 VAC, 60 Hz power outlet only. 5.0 Power Supply 5. Secure the transformer to the outlet with the screw Primary Power Terminals 1 and 2 provided.
  • Page 20: Figure 5: Non-Power-Limited Wiring

    D7212GV2 | Operation and Installation Guide | 5.0 Power Supply 4. Connect the red battery lead to Terminal 5, and Caution: The battery terminals and wire are then to the positive (+) side of the battery. not power limited. A 6.4 mm (0.250 in.) Warning: High current arcs are possible.
  • Page 21: Replacing The Battery

    D7212GV2 | Operation and Installation Guide | 5.0 Power Supply 5.2.3 Replacing the Battery Figure 6: Charging and Battery LEDs Replace batteries every 3 to 5 years under normal use. Record the date of installation directly on the battery. LEDs Off When Normal...
  • Page 22: Battery Discharge And Recharge Schedule

    D7212GV2 | Operation and Installation Guide | 5.0 Power Supply A shorted battery condition is created either by a shorted cell inside the battery or by a short on Terminals 4 and 5. A shorted battery might cause the control panel to operate in an unsafe way. This condition generates WATCHDOG RESET reports.
  • Page 23 D7212GV2 | Operation and Installation Guide | 5.0 Power Supply Table 8: Charging Status and Low Battery LEDs Type Action Color State Charging Status LED Yellow Shows the changing status of the battery. Refer to Figure 6 on page 21 for location.
  • Page 24: Power Outputs

    D7212GV2 | Operation and Installation Guide | 6.0 Power Outputs Continuous Power Output 6.0 Power Outputs Terminals 3, 8, and 32 The continuous current draw for powered devices Circuit Protection connected to Terminals 3, 8, and 32, and the accessory Three Positive Temperature Coefficients (PTCs) protect connector must not exceed 1.4 A.
  • Page 25: Terminals 6 And 7

    D7212GV2 | Operation and Installation Guide | 6.0 Power Outputs 6.4.2 Terminals 6 and 7 6.4.4 Terminal 8 When activated, Terminals 6 (Relay A) and 7 (Relay Terminal 8 provides continuous positive (+) 10.2 VDC B), provide positive (+) 10.2 VDC to 13.9 VDC power to 13.9 VDC power.
  • Page 26: Telephone Connections

    D7212GV2 | Operation and Installation Guide | 7.0 Telephone Connections Figure 7: RJ31X Wiring Telephone Connections Registration RJ31X RING (red) TIP (green) The Bosch Security Systems D7212GV2 Control Panel is registered with the Federal Communication Commission (FCC) under Part 68, for connection to the public telephone system using an RJ31X or RJ38X jack installed by the local telephone company.
  • Page 27: Phone Led (Red)

    Programming determines what the response The D7212GV2 Control Panel can send events over is. Refer to Phone Parameters in the D7212GV2 Program the SDI Bus to a DX4020 or D9133TTL-E Network Entry Guide (P/N: F01U003804).
  • Page 28: On-Board Points

    D7212GV2 | Operation and Installation Guide | 8.0 On-Board Points The number of normally-open and normally-closed 8.0 On-Board Points detection devices each sensor loop can supervise is limited only by the resistance on the loop. The total Terminals 11 to 22 Description resistance for the wire length and contacts, minus the end-of-line (EOL) resistor, must not exceed 100 Ω.
  • Page 29: Point Response Time

    D7212GV2 | Operation and Installation Guide | 8.0 On-Board Points Point Response Time Wiring Information for Installations Using the Ademco AB-12 The control panel scans on-board and off-board point sensor loops every 300 ms. The Debounce program Bell/Housing item in the Point Assignment section of the software 1.
  • Page 30 D7212GV2 | Operation and Installation Guide | 8.0 On-Board Points Figure 10: Wiring for Installation Using the Ademco AB-12 Bell/Housing CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet...
  • Page 31: Off-Board Points

    9.1.1 POPIT Modules The D7212GV2 can use point of protection input transponder (POPIT) modules to provide a maximum of 32 off- board points, bringing the total number of points the D7212GV2 can monitor to 40. Each off-board point requires a POPIT Module.
  • Page 32: D7212Gv2 Responses To Missing Point Conditions

    D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points Table 12: Off-Board Point Errors Error Condition Result Additional Information +/- leg of the data expansion bus has a Ground Fault event short-circuit to earth ground, with Ground Fault Detect enabled...
  • Page 33 D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points Figure 11: Connecting the D8125 POPEX to the D7212GV2 Panel Low Battery Battery D9127U/T D9127U/T D9127U/T amming E CONNECTIONS CLASS 2 TRANS POWER + 16.5 VAC 40 VAC Model D1640...
  • Page 34: Installing The D8125 Popex Module

    POPIT label sheets. One set 881 (2890) is marked “Bank 1” for use with the D7412GV2 and 1402 (4600) D7212GV2. The other set is marked “Bank 2” for use 2231 (7320) with the D9412GV2 and D9112. Use the Bank 1 sheet 3551 (11,650) later to label the POPITs.
  • Page 35: Wiring Data Expansion Loops To Popex Modules

    9.3.4 Wiring Data Expansion Loops to POPEX Modules For the D7212GV2, Points 9 to 40 can use Each POPEX Module has two positive (+) and two either D8127 or D9127 POPITs. negative (-) data expansion loop terminals. Up to 32 POPITs can be connected to one D8125 on the 9.3.7...
  • Page 36: Popit Labels

    Walk Test and Service Walk Test Do Not Show Up to four D8128Ds can be connected to the Extra Points: If the point assignment switches on a D7212GV2 Control Panel (three points can be used on POPIT or OctoPOPIT are set incorrectly, missing and the last OctoPOPIT).
  • Page 37: Installation

    D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points 9.4.4 Setting the OctoPOPIT Switches Figure 13: D8128D OctoPOPIT Layout The D8128D OctoPOPIT has two sets of DIP switches (Figure 13). Use the DIP switches on the top of the unit (with the terminal strip along the left edge) to set the address for the OctoPOPIT.
  • Page 38: Mounting Octopopits

    D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points • Use the point DIP switches to disable conflicting Wire the D8128D to the terminal strip on the points, such as when a D9210B Access Control Module side of the POPEX Module (refer to Using the...
  • Page 39 D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points Figure 14: Connecting D8128D OctoPOPITs to the D7212GV2 First Address on ZONEX Bus 1 First Address on ZONEX Bus 1 Low Battery Battery amming E CONNECTIONS CLASS 2 TRANS POWER + 16.5 VAC 40 VAC...
  • Page 40: Connectors

    D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points ® Using Molex Connectors Each D8128D Module is supplied with a 30 cm (12 in.) female-to-female Molex cable assembly. P1 and P2 are Molex connectors that parallel the COM, IN, OUT, and +12 VDC terminals on the terminal strip.
  • Page 41: Octopopit Sensor Loops

    D7212GV2 | Operation and Installation Guide | 9.0 Off-Board Points 9.4.7 OctoPOPIT Sensor Loops Figure 16: D8128D OctoPOPIT Sensor Loops Only the resistance on the loop limits the number of normally-open or normally-closed detection devices each sensor loop can supervise. Resistance on each sensor loop must be less than 100 Ω...
  • Page 42: Off-Board Relays

    Use the D8129 OctoRelay to add relay outputs to the 10.2 Configuring the D8129 OctoRelay system in groups of eight. The D7212GV2 allows up to Five switches on the OctoRelay determine the relay 24 relay outputs. Review Section 6.0 Power Outputs on numbers for the eight relay outputs (Table 17).
  • Page 43: Relay Outputs

    D7212GV2 | Operation and Installation Guide | 10.0 Off-Board Relays 10.3 Relay Outputs Relay outputs can activate when you are setting the OctoRelay switches or programming the control panel. Disconnect equipment connected to relay outputs when you perform these functions.
  • Page 44: Arming Devices

    Keypads connect to the total number of keypads that can be connected to the control panel in parallel (Table 19). system. Refer to Keypad in the D7212GV2 Program Entry Guide (P/N: F01U003804) for complete programming Table 19: Keypad Connections details on keypad options.
  • Page 45: Figure 18: Power At Keypads

    D7212GV2 | Operation and Installation Guide | 11.0 Arming Devices Wire Limits for Individual Keypads The control panel and the D8132 (or other • Limit most keypads to 610 m (2000 ft) per run. power supply) must share COMMON. •...
  • Page 46: D268/D269 Independent Zone Control, D279A Independent Zone Control

    D7212GV2 | Operation and Installation Guide | 11.0 Arming Devices 11.4.2 Programming 11.3 D268/D269 Independent Zone Refer to Point Assignments in the D7212GV2 Program Control, D279A Independent Zone Entry Guide (P/N: F01U003804) for the correct Control programming for points used for keyswitches.
  • Page 47 If the point to which the keyswitch is connected is programmed for a momentary contact, shorting the arming circuit toggles the area’s arming state between armed and disarmed. All faulted points are force armed, regardless of the entry in the FA Bypass Max program item. Refer to Point Assignments in the D7212GV2 Program Entry Guide (P/N: F01U003804).
  • Page 48: Sdi Devices

    D7212GV2 | Operation and Installation Guide | 12.0 SDI Devices 12.3.1 Switch Settings 12.0 SDI Devices Switches on the D9131A assign a unique address (17 to 19) for each printer. The address determines if the 12.1 Description printer is supervised, the area scope of the printers, and the area to which the printer is assigned.
  • Page 49: Address Settings

    Used as an External Modem The D9133DC can operate as an external modem when using Remote Programming Software (RPS) with the control panel. Refer to the D7212GV2 Program Entry Guide (P/N: F01U003804) for programming details. Bosch Security Systems, Inc. | 5/05 | F01U003805B...
  • Page 50: Network Interface Modules

    D7212GV2 | Operation and Installation Guide | 12.0 SDI Devices 12.5.2 Network Interface Modules Figure 23: D9133TTL-E Jumper Settings The Bosch Security Systems DX4020 Network Interface Module and D9133TTL-E Network Interface Module are four-wire powered SDI devices that provide connection for two-way communication over Ethernet networks to the D7212GV2.
  • Page 51: Programmer Connections

    D7212GV2 | Operation and Installation Guide | 13.0 Programmer Connections 13.0 Programmer Connections 13.1 Programmer Connector Refer to the D5200 Operation Manual (P/N: 74-06176-000) for complete information on using the D5200 programmer. To connect and disconnect the programmer: 1. Lock the Reset Pin (Figure 24).
  • Page 52: D7212Gv2 Faceplate

    SWITCHED AUX service is to be provided with this equipment. Terminal D7212GV2 Control Panel is UL Listed For Central Station, Local, Remote Station and NOT USED RELAY C Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm and Encrypted Line Security when communicating via a network.
  • Page 53: Appendix A: System Wiring Diagrams, Issue A

    D7212GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A Appendix A: System Wiring Diagrams, Issue A Figure 26: D7212GV2, Power Supply Side D113 CHGR- BAT 2- BAT 2+ VAUX+ BAT 1- SUPV BAT 1+ CHGR+...
  • Page 54: Figure 27: D7212Gv2, Input Points And Peripheral Devices

    D7212GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A Figure 27: D7212GV2, Input Points and Peripheral Devices CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet...
  • Page 55: Figure 28: D7212Gv2, Sdi Devices

    D7212GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A Figure 28: D7212GV2, SDI Devices D1255 D1256 D1257 D1260 D7212GV2 PERIPHERAL DEVICE CONNECTIONS CLASS 2 TRANSFORMER POWER + 16.5 VAC 40 VA 60 Hz Model D1640...
  • Page 56: Appendix B: Point Address Chart

    D7212GV2 | Operation and Installation Guide | Appendix B: Point Address Chart Appendix B: Point Address Chart Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A bullet (•) in the switch column indicates that the switch is set to ON.
  • Page 57 D7212GV2 | Operation and Installation Guide | Appendix B: Point Address Chart Notes Bosch Security Systems, Inc. | 5/05 | F01U003805B...
  • Page 58: Specifications

    Telephone Connection: RJ31X or RJ38X jack can connect the control panels. Connections Two telco lines: Bosch Security Systems D928 Dual Phone Line Module required for two phone line service. Supervision supplied by the control panel. Battery Discharge 13.9 VDC Charging float level.
  • Page 59 D7212GV2 | Operation and Installation Guide | Specifications Notes Bosch Security Systems, Inc. | 5/05 | F01U003805B...
  • Page 60 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2005 Bosch Security Systems F01U003805B...