Haier GE NF80US Service Manual page 16

80% upflow/horizontal single stage constant torque gas furnace
Hide thumbs Also See for GE NF80US:
Table of Contents

Advertisement

Blower Compartment
IMPORTANT
Each blower is statically and dynamically balanced as
an assembly before installation in the unit.
NF80US units are equipped with a constant torque ECM
motor. It has a DC motor coupled to an electronic control
module both contained in the same motor housing. The
motor is programmed to provide constant torque at each of
the five selectable speed taps. Each tap requires 24 volts
to energize.
Input Voltage Requirements
The circuit is designed to be operated with AC voltage. To
enable a tap requires 12 to 33VAC. Expected current draw
will be less than 20mA.
Troubleshooting the Motor
Troubleshooting the motor is an easy process. Follow
steps below.
1.
Shut off power to unit.
2.
Remove input plugs P48 and P49 from motor. See
Figure 14 for troubleshooting procedure.
If correct voltage is present in tests 1 and 2 and motor is
not operating properly, replace motor. The motor is not field
repairable.
If replacing the indoor blower motor or blower wheel is
necessary, placement is critical. The blower wheel must
be centered in the blower housing as shown in Figure 12.
When replacing the indoor blower motor the set screw
must be aligned and tightened with the motor shaft as
shown in Figure 13.
Figure 12. Blower Wheel Replacement
ALIGN AND TIGHTEN SET SCREW WITH
FLAT SIDE OF MOTOR SHAFT
Housing Hub
Motor
Shaft
Page 16
Center Blower Wheel
in Blower Housing
Set Screw
Figure 13.
31-5000735 Rev. 0