Haier GE NF80DS Installation Instructions Manual page 25

Warm air gas furnace
Table of Contents

Advertisement

RED LED
RECALL BUTTON
Figure 24. 103217-03 Integrated Control
(Automatic Hot Surface Ignition System)
W
C
Push Button
Diagnostic LED
Error Recall
Figure 25. 107163-01 Integrated Control
507332-02G / 31-5000663
BLOWER OFF DELAY
PARK
R
G
Y
Heating Blower Off
Delay Selector Switch
1/4" Quick Connect Terminal Designations
120V HUM
LINE
XFMR
CIRC
EAC
HUM24
NEUTRALS (5)
3/16" Quick Connect Terminal Designations
COOL
HEAT
FAN
PARK (3)
FS
24V COM
Table 13. Terminal Designations
(Applicable to 103217-03 and 107163-01 Controls)
Issue 2209
Power for Humidifier (120VAC)
Incoming Power Line (120VAC)
Transformer Primary (120VAC)
Indoor Blower Motor (120VAC)
Electronic Air Cleaner (120VAC)
Power For Humidifier (24VAC)
Neutral
Cool Speed From Indoor Blower Motor
(24VAC)
Heat Speed From Indoor Blower Motor
(24VAC)
Continuous Fan Speed From Indoor
Blower Motor (24VAC)
Terminals For Unused Motor Speed
Taps
Flame Sensor Electrode (120VAC)
Common (24VAC)
Page 25 of 35