Electronics compartment
Assignment of the plug
connector
Supplementary electron-
ics - Additional current
output
24
Contact pin
Pin 2
Pin 3
Pin 4
5.6

Double chamber housing with DISADAPT

Fig. 18: View to the electronics compartment with DISADAPT for connection of
the external display and adjustment unit
1
DISADAPT
2
Internal plug connection
3
Plug connector M12 x 1
Fig. 19: View to the plug connector M12 x 1
1
Pin 1
2
Pin 2
3
Pin 3
4
Pin 4
Contact pin
Pin 1
Pin 2
Pin 3
Pin 4
5.7

Supplementary electronics

To make a second measured value available for use, you can use the
supplementary electronics - additional current output.
SITRANS LG260 - Operating Instructions
Colour connection ca-
ble in the sensor
White
Blue
Black
4
1
Colour connection ca-
ble in the sensor
Brown
White
Blue
Black
Terminal, electronics
module
6
7
8
1
2
3
3
2
Terminal, electronics
module
5
6
7
8
PBD-51041057

Advertisement