4.5. V-COM Adjust(Only LGD(M+S) Module)
V
4.6. Outgoing condition Configuration
4.7. Internal pressure
- 13 -
HD(LED)
37LD460-SA 26LE5300-SA 26LE6500-SA 42LE4600-SA
42LD460-SA
47LD460-SA
32LD420-SA
42LD420-SA
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
Data (R ,G,B ) &
Con t rol si gnal
Data (R ,G,B ) & C ont ro l s ignal
Ti m i n g
S
Co nt r o ll e r
Da t a I n p u t
Da t a I n p u t
Y
S
T
E
Po w e r
Power Input
Po w e r I n p u t
Blo ck
M
V
COM
COM
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing "ADJ" key, then
Enter V-Com Adjust mode by pushing "
Com"
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the "OK" key to store value. Then the message
"Saving OK" is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
- When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board's ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
FHD Small(LED) FHD(LED)
47LE4600-SA
55LE4600-SA
32LE5300-SA
37LE5300-SA
42LE5300-SA
47LE5300-SA
55LE5300-SA
Circuit Block
Ga mma
Re f e r e nce V o ltage
Gamm a Reference
Volta ge
Con t rol si gnal
So urce D r i v e I C
Column Line
Pane l
V
COM
C
C
LC
ST
Liquid
Crys tal
TFT
Row Li ne
G
" key at "10. V-
LGE Internal Use Only

Advertisement

loading

This manual is also suitable for:

42le46300-sa