Installation
Front view
a Mains connection cable
b Control panel
c Condensed water container
– empty after every drying cycle
d Door
– do not open during drying
11692300-00
e Heat exchanger access panel
– do not open during drying
f Four height adjustable screw feet
g Cool air intake grille
– do not obstruct with a laundry bas-
ket or other objects
h Hose for external drainage of con-
densed water

Advertisement

loading

Summary of Contents for Miele TCB140 WP

  • Page 1 *INSTALLATION* 11692300-00 Installation Front view a Mains connection cable e Heat exchanger access panel – do not open during drying b Control panel f Four height adjustable screw feet c Condensed water container g Cool air intake grille – empty after every drying cycle –...
  • Page 2: Installation

    *INSTALLATION* 11692300-00 Installation Rear view  If the tumble dryer is being transpor- ted on its side, it must be tipped onto its left or right side. a Protruding lid for holding when mov-  If the tumble dryer is being transpor- ing the tumble dryer (see arrows) ted upright and you are using a hand b Drain hose for condensation...
  • Page 3 - Air the room where the tumble dryer The tumble dryer must stand perfectly is located. level to ensure safe and proper opera- - Contact the Miele Customer Service tion. Department. Downtime after installation  Damage to the tumble dryer by switching it on too soon.
  • Page 4 *INSTALLATION* 11692300-00 Installation Ventilation The heat pump that is essential to the operation of this tumble dryer The cool air intake at the front of the generates a great deal of heat inside tumble dryer must not be blocked or its casing.
  • Page 5: Additional Installation Requirements

    – Washer-dryer stack heat. The tumble dryer can be combined with Make sure there is adequate room a Miele washing machine in a washer- for warm air from the dryer to be dir- dryer stack. The appropriate Miele ected away.
  • Page 6: External Condensed Water Outlet

    *INSTALLATION* 11692300-00 Installation Installation conditions requiring a External condensed water out- non-return valve  Danger of condensed water Note back-flow. When drying is in progress, con- Water could flow back into the densed water is pumped into the con- tumble dryer or be drawn into it. densed water container through the Back-flow water could damage the drain hose which is located at the...
  • Page 7 *INSTALLATION* 11692300-00 Installation Arranging the drain hose Examples Drainage into a sink or floor gully  Damage to the drain hose through incorrect handling. Use the hose holder to secure the drain hose. The drain hose can suffer damage and leak. Do not pull on the drain hose and do not stretch it or allow it to become kinked.
  • Page 8 *INSTALLATION* 11692300-00 Installation  Fit adapter 1 to the sink drain outlet Direct connection to a sink drain outlet using nut 2. Use the hose holder, the adapter, the The nut is usually fitted with a washer hose clips and the non-return valve which must be removed.
  • Page 9: Electrical Connection

    If the connection cable is damaged, it must only be replaced with a specific connection cable of the same type (available from the Miele Customer Ser- vice Department). For safety reasons, such replacement may only be carried out by a qualified technician or the Miele Customer Service Department.