4 way output expander module

Advertisement

Module Address Switches and Output Numbering
Table 2: and Table 3: list the module address settings and corresponding output numbers that apply when adding
output expanders to the listed panels. Each output expander module added to the Solution 16i will provide a maxi-
mum of 4 additional outputs.
Only one CM710B can be assigned to each address. All mod-
i
ules are supplied from the factory set to address 1. You must
Note
power cycle the panel or perform a LAN scan whenever you
change the module address. The LAN must be in the unlocked
state or the LAN scan will not find new modules.
Panel Output Assignments
The following tables list the output numbers which become available when adding output expander modules to the
system.
Table 3: CM710B Address Configuration On Solution E and Solution 144 Panels
Copyright © 2012
Solution 16i Panel
Address Setting
Module
Number
SW1 SW2 SW3 SW4
Control Panel
1 =
OFF OFF OFF OFF
1 x CM710B can be fitted to the Solution 16i panel.
Table 2: CM710B Address Configuration On Solution 16i Panel
Solution 144 and Solution E Panels
Address Setting
Module
Number
SW1 SW2 SW3 SW4
Control Panel
Virtual Outputs
1 =
OFF
OFF
OFF
2 =
ON
OFF
OFF
3 =
OFF
ON
OFF
4 =
ON
ON
OFF
5 =
OFF
OFF
ON
6 =
ON
OFF
ON
7 =
OFF
ON
ON
8 =
ON
ON
ON
9 =
OFF
OFF
OFF
10 =
ON
OFF
OFF
11 =
OFF
ON
OFF
12 =
ON
ON
OFF
13 =
OFF
OFF
ON
14 =
ON
OFF
ON
15 =
OFF
ON
ON
16 =
ON
ON
ON
Up to 16 x CM710B can be fitted to the Solution E panel.
Up to 8 x CM710B can be fitted to the Solution 144 panel.
E&OE
Figure 1: Address Switch Activation
Output
Numbers
1 to 4
5 to 8
Output
Numbers
1 to 5
6 to 8
OFF
9 to 12
OFF
13 to 16
OFF
17 to 20
OFF
21 to 24
OFF
25 to 28
OFF
29 to 32
OFF
33 to 36
OFF
37 to 40
ON
41 to 44
ON
45 to 48
ON
49 to 52
ON
53 to 56
ON
57 to 60
ON
61 to 64
ON
65 to 68
ON
69 to 72
P/N: CM710BIRG Rev 1.3
ON
Position
Page