Technical specifications

8.2 Standards and approvals

Classification of the mechanical environ‐
ment
Vibratory load during operation
Shock load during operation with shock-
sensitive components
EMC conducted / radiation
1) The system installer ensures the system is sealed properly according to IP65, IP classification has not been
checked by UL, UL TYPE 1.
2) Open-type equipment according to UL 61010.
3) The customer must ensure that the product, with the rear cover to be attached by the customer, meets
the requirements for flame resistance of the material according to UL 94 V-1 and the mechanical stability /
fire protection requirements / touch protection according to UL 61010.
4) If power supply units with primary-side supplies up to 600 VAC (line-to-neutral voltage) have to be
deployed, the transient voltages on the primary side of the power supply unit must be limited to 4000 V.
5) Connect the device only to a power supply that is compliant with protective extra-low voltage (PELV)
requirements according to UL 61010.
8.1

EMF assessments for 24 V components

The 24 V components, e.g. control systems (NCU, MCU, PPU), PCUs/IPCs, operator panels,
handheld terminals and machine control panels do not generate any appreciable
electromagnetic fields.
No minimum clearance has to be maintained for 24 V components.
8.2
Standards and approvals
Figure 8-1
The operator panels and the safety-relevant accessories satisfy the requirements and protection
objectives of the following EC directives. The operator panels and the safety-relevant accessories
comply with the harmonized European standards (EN), promulgated in the Official Journals of
the European Community:
• 2014/30/EU "Electromagnetic Compatibility" (EMC Directive)
• Directive 2011/65/EC on the restriction of the use of certain hazardous substances in
electrical and electronic devices (RoHS II)
32
CE marking
KB 1500
Class 3M2 according to EN 60721-3-3
Frequency range: 10 – 200 Hz
Deflection at 9 – 18 Hz: 1.5 mm
Acceleration at 18 – 200 Hz: 2 g
Acceleration: 5 g
Shock duration: 30 ms
Load: 3 x in each direction
Class C2 according to EN 61800-3
Full CNC keyboards: KB 1500 and KB 1900
Equipment Manual, 09/2022, A5E52185085B AB
KB 1900
Acceleration: 15 g
Shock duration: 11 ms