TROUBLESHOOTING
E-28 Monitoring function does not display "Bucket DUMP" normally
• Monitoring function does not display
Trouble
"Bucket DUMP" normally.
Related
• 6-bit position of bucket DUMP oil pressure switch (Code: 021, Right of lower line)
information
Defective bucket DUMP oil
pressure switch
1
(Internal disconnection or
short circuit)
Disconnection in wiring
harness
2
(Disconnection in wiring
harness or defective
contact in connector)
Possible causes
and standard
Short circuit with chassis
value in normal
ground in wiring harness
state
3
(Contact with ground
circuit)
Short circuit with power
4
source in wiring harness
(Contact with 24-V circuit)
Defective governor and
5
pump controller
20-454
(1)
Cause
Standard value in normal state/Remarks on troubleshooting
aPrepare with starting switch OFF, then start engine and carry out trou-
bleshooting.
S05 (male)
Between (1) and (2)
aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch.
Wiring harness between C03 (female) (19) and
S05 (female) (1)
Wiring harness between S05 (female) (2) and
chassis ground (A16)
aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch.
Between C03 (female) (19) – S05 (female) (1)
wiring harness and chassis ground
aPrepare with starting switch OFF, then turn starting switch ON and car-
ry out troubleshooting.
Between C03 (female) (19) – S05 (female) (1)
wiring harness and chassis ground
aPrepare with starting switch OFF, then start engine and carry out trou-
bleshooting.
Between (19) and
chassis ground
The monitoring function (special function) of the monitor
panel does not display "Bucket DUMP" normally.
Right work equipment
control lever
Neutral position
Bucket DUMP position
Right work equipment
C03
control lever
Neutral position
Bucket DUMP position
E-28
Resistance
Min. 1 Mz
Max. 1 z
Max. 1 z
Resistance
Max. 1 z
Resistance
Resistance
Min. 1 Mz
Voltage
Max. 1 V
Voltage
20 – 30 V
Max. 1 V
PC130-7