• By turning on the L. ONLY switch, the listen-only mode can be set. (Switch 6)
Note : • Other switches (7 and 8) are not used.
• The contents set by the address swi tch are read upon power on. Be
sure to set the address switch before power on.
3)
T r a n s i t i o n to the local mode
Switching from the remote mode (GP-IB operating) to the local mode
CD
PD power supply
I f the LCL key on the panel of t h i s component i s pressed, the PD power
supply changes from the remote mode to the local mode and operat ion on
the panel i s allowed.
®
PA power supply
By switching the CV/CC external control switch S1/S2 on the rear of the
PA power supply from REMOTE to LOCAL, the l o c a l mode of the PA power
supply i s set and operat ion on the panel i s allowed.
I f OP-13 i s not used, s w i t c h e x t e r n a l r e s i s t o r S2/S4 to LOCAL at the
same time.
4)
T r a n s i t i o n to the remote mode
When the contro11er sends the s e t t i n g command f o r the contro1 led power
supply according to the GP-IB input cord format, the control led power supply
is set into the remote mode (controlled through the GP-IB bus).
Be sure to set them to OFF.