MAINTENANCE AND A D J U S T M E N T
Maintenance
Removing the case (Fig. 7):
1. Remove the 2 screws on top of the case, 4 screws on side and 4 screws on
bottom using a Phillips type screwdriver.
2. Remove the. upper case by pulling upward and the lower case by pulling
.downward.
Power voltage selection: (Fig. 8)
When operating the FL-1 8 0 on 100V, 120V or 2 2 0 V , set the voltage selector switch
on the rear panel to the correct position.
For operation on 100V or 120V, take out the fuse (0.3A) in the fuse holder on the
rear panel, and replace it with a 0.5A fuse.
Note:
When changing the power voltage, be sure to remove the power cord from the
A C outlet.
14
Fig. 7 Removing the case
Fig. 8 Power voltage selection