Samsung SSA-R1003 Quick Manual page 35

Hide thumbs Also See for SSA-R1003:
Table of Contents

Advertisement

Available languages

Available languages

Item
Connect the DC+12V to the red line.
Power
Supply Unit
Connect GND to the black line.
Connect the green line of the product to the Wiegand D0 input port of the controller.
Wiegand
Connection
Connect the white line of the product to the Wiegand D1 input port of the controller.
LED
To control the LED indicators, connect the yellow line to the output port (relay) of the
Control
controller.
Buzzer
To control the built-in buzzer, connect the blue line to the output port (relay) of the
Control
controller.
RS-232
Connect to the COM port of the PC. (Connect pin 2 of the DB-9 connector to the brown
Connection
line; connect the GND (black) line of the device to pin 5 of the DB-9 connector.)
Cable Color
QUICK GUIDE
11
English_

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssa-r1103

Table of Contents