SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
The pre-programmed alarm responses will activate automatically through this manual activation.
The programmed parameters for the alarm, such as latching mode, buzzer setting and relays will
determine the alarm actions. In addition, the camera associated with the alarm will be recorded as
programmed.
To deactivate this function, simply reset the alarm as normal by pressing the ALARM key.
You can also specify how the images from the alarmed cameras are to be recorded (interleaved,
exclusive or no change) and whether some or all of the alarms are to be enabled or disabled. The
alarm history can be viewed for the last 100 alarms and you can specify whether the unit's alarm
output relays are normally open or normally closed.
The ALARMS menu appears as follows:
INPUT CONFIGURATION
The alarm inputs are configured as zero potential relay contacts, individually programmable via the
menu to be normally open (NO) or normally closed (N/C). The factory default is N/O for all inputs.
ALARM LATCH
There are three ways of alarm latching:
q
Latched until the operator cancels it,
q
Latched for a pre-set time (timed out), or
q
Not latched (Transparent)
Alarm latching is controlled by a single setting (global) .
Latched alarms:
Alarms are latched as they become active.
acknowledges it. There is no time out period. When the operator acknowledges the alarm, it will be
cleared whether the alarm input is still active or not. Alarms that have been acknowledged by the
operator will not be reactivated unless the alarm input has ceased and then restarts.
Timed out alarms:
48
JVC PROFESSIONAL, IMAGING PRODUCTS
Input Configuration
Alarm Latch
External Alarm Action
Record Mode
Enable / Disable
Alarm History
Link to a Macro
Fullscreen Alarm
Relay Configuration
Buzzer Setup
Videoloss Action
Exit
An alarm will stay active until the operator