Download Print this page

Sony BKP-5974 Quick Start Manual page 4

Dc power unit

Advertisement

2
Remove the AC power unit.
1 Remove the two screws on the top of the AC
power unit.
2 Turn the CCU-550/550P upside down, and
remove the two screws on the bottom of the
AC power unit.
For the purchasers of the CCU-550P
Keep the screws and spring washers for use in
reattaching the AC Power Unit at a later time.
3 Turn the CCU-550/550P back and pull the AC
power unit out starting with the front end
behind the front panel.
B
Disconnect the yellow connector (A) from the
internal AU-236 board and disconnect the 5-
pin connector (B) at the rear end.
4 Lay the AC power unit on its side and
disconnect the 40-pin connector (C).
C
3
Attach the DC Power Unit.
Do the procedure in 3 and 4 in Step 2 above in
reverse; i.e., connect the 40-pin and 5-pin
connectors at the rear end, connect the yellow
cable, and then attach the DC Power Unit to the
CCU-550/550P starting with the rear end.
Note
When attaching the DC Power Unit, make sure that
the yellow cable is not caught between the CCU-550/
550P and the DC Power Unit. Damage to the yellow
cable may cause a short-circuit within the unit.
4
Fasten the four screws removed in Step 2 and
replace the top panel of the CCU-550/550P.
Specifications
Power requirements
Power consumption
Mass
Dimensions
A
Supplied accessories
Note
Select the DC power cable that satisfies the power
rating of 10 amperes.
DC 10.5-17 V
Maximum 9.5 A
Approx. 1.7 kg (3 lb 12 oz)
60 × 112.5 × 295 mm
× 4
× 11
(2
3
/
1
/
5
/
in.) (w/h/d)
8
2
8
not including the projecting parts
Fuse (20 amperes)
Hexagon wrench (2mm) (for
CCU-550P)