Haier J Series Service Manual page 19

Table of Contents

Advertisement

Refrigeration/dehumidification mode::
Serial No.
1
2
3
4
5
6
7
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system.
When the starting ability is not the maximum, its maximum frequency limitation is calculated by
the following equations:
F( reference frequency)=∑Fi( reference frequency)
Note - valid internal machine (starting and running in accordance with the state) to participate
in the calculation
Fi( reference frequency)=Fei(Computed base frequency)*Kw
(Outer ring temperature coefficient(External ring temperature on frequency limitation
section))*Pi(Temperature difference between the weight) *Ki(Wind speed weight)
(Note: the reference frequency Fi is rounded after calculation and no rounding is performed;)
i= machine A, machine B...
Refrigeration/dehumidification:
Pi
The percentage of
the rated frequency P
Heating mode
Pi
The percentage of the
rated frequency P
The indoor set
Breeze Low
airflow speed
60
Ki
Temperature scope
Wh_c<16
Wh_c<23
Wh_c<29
Wh_c<32
Wh_c<40
Wh_c<48
Wh_c>48
< 0
<1
80%
85%
< 0
<1
80%
85%
Medium High
70%
85%
17
Frequency limitation
Max_hz1 37 HZ
Max_hz2 45 HZ
Max_hz3 56 HZ
Max_hz4 63 HZ
Max_hz5 90 HZ
Max_hz4 90 HZ
Max_hz5 90 HZ
< 2
< 3
< 4
90%
95 %
100%
< 2
< 3
< 4
90%
98%
105 %
Strong Quiet Healthy
100% 108%
60%
Functions and control
≥ 4
110%
≥ 4
115%
airflow
60%
Domestic air conditioner