    Brocade 8Gb SAN Switch for HP BladeSystem c-Class user guide *5697-7483* Part number: 5697-7483 First edition: July 2008...
  • Page 2 © Copyright 2008 Brocade Communications Systems, Incorporated The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    Other HP websites ........
  • Page 4 ........Rebooting the switch ........
  • Page 5 Index ....... 61 Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 6 1 Brocade 8Gb SAN Switch components 2 8Gb SAN Switch external ports ......3 Carton contents...
  • Page 7 18 General specifications ......19 8Gb SAN Switch physical dimensions ..... . .
  • Page 9: About This Guide

    About this guide This guide provides information about setting up and configuring the Brocade 8Gb SAN Switch for HP BladeSystem c-Class. Throughout this guide the short product name is used, 8Gb SAN Switch. Intended audience This guide is intended for system administrators and technicians with knowledge of: •...
  • Page 10: Hp Contact Information

    In other locations, see the Contact HP worldwide (in English) web page: http://welcome.hp.com/country/us/en/wwcontact.html • In the United States, for contact options see the Contact HP United States web page: http://welcome.hp.com/country/us/en/contact_us.html • Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week.
  • Page 11: Subscription Service

    TIP: Provides helpful hints and shortcuts. Subscription service HP strongly recommends that customers register online using the Subscriber's choice website: http://www.hp.com/go/e-updates. Subscribing to this service provides you with e-mail updates on the latest product enhancements, newest driver versions, and firmware documentation updates as well as instant access to numerous other product resources.
  • Page 12 About this guide...
  • Page 13: Overview

    1 Overview The Brocade 8Gb SAN Switch for HP BladeSystem c-Class (referred to in the rest of this manual as the 8Gb SAN Switch) is a Fibre Channel (FC) switch that supports link speeds of up to 8 Gbps. The 8Gb SAN Switch can operate in a fabric containing multiple switches or as the only switch in a fabric.
  • Page 14: Component Identification

    Reset button Port side of the 8Gb SAN Switch Figure 2 Table 3 identify 8Gb SAN Switch external ports (ports 17 through 20, and ports 21 through 0). Reset Figure 2 8Gb SAN Switch external ports Table 3 Identifying 8Gb SAN Switch external ports...
  • Page 15: Internal Ports Summary

    Redundant HP Onboard Administrator (OA) to ensure management access to the switch NOTE: The HP Onboard Administrator is the enclosure management module used to support and manage the HP BladeSystem c-Class and all managed devices used in the enclosure. 8Gb SAN Switch licensing The 8Gb SAN Switch integrates one of three license options that complement existing HP product lines.
  • Page 16: Isl Trunking Groups

    • Fabric Watch • Advanced Performance Monitoring • Extended Fabrics For information on any of these features, refer to the latest version of the HP StorageWorks Fabric OS administrator guide. Overview Figure HP StorageWorks Fabric OS administrator guide Part number...
  • Page 17: Supported Sfp Transceiver Options

    Option HP 4Gb Long Wave B-Series FC SFP 1 Pack - 10km HP 4Gb Long Wave B-Series FC SFP 1 Pack - 30km Table 6 HP 8Gb Short Wave B-Series FC SFP+ 1 Pack, order number AJ716A Distance 8Gb performance...
  • Page 18 Overview...
  • Page 19: Setup

    One Brocade 8Gb SAN Switch; models include: • Brocade 8/12 SAN Switch for HP BladeSystem c-Class with twelve active ports • Brocade 8/24 SAN Switch for HP BladeSystem c-Class with sixteen internal and eight external active ports • Brocade 8/24 SAN Switch Power Pack+ for HP BladeSystem c-Class with sixteen internal and eight external active ports scale: 3/8"...
  • Page 20: Installation And Safety Considerations

    Installation and safety considerations The 8Gb SAN Switch installs in the I/O bays in the rear of the HP BladeSystem c-Class enclosure. Refer to the appropriate BladeSystem Enclosure Setup and Installation Guide for specific enclosure requirements. Installing multiple switches If you do not have a DHCP server connected to the OA, install and configure one 8Gb SAN Switch at a time.
  • Page 21: Releasing The Installation Handle

    Handle latch Installation handle (released) NOTE: The Brocade 8Gb SAN Switch is a hot-pluggable device. The enclosure power may be on or off during installation. Align the Brocade 8Gb SAN Switch with the appropriate interconnect bay according to your enclosure’s specific configuration. Push the switch firmly into the interconnect bay. See...
  • Page 22: Oa Power Verification

    If there is no mismatch, the OA powers up the switch. If the switch does not power up, check the enclosure and switch status with the OA web interface. Refer to the HP BladeSystem Onboard Administrator User Guide.
  • Page 23: Set The Switch Ethernet Ip Address

    Open a web browser and connect to the active OA. Enable EBIPA for the corresponding interconnect bay. Click Apply to restart the switch. Verify the IP address using a Telnet or SSH login to the switch, or by selecting the switch in the OA GUI Rack Overview window. 26477a...
  • Page 24: Using External Dhcp

    Document the DHCP-assigned address by selecting the switch from the OA GUI Rack Overview window. Verify the IP address using a Telnet or SSH login to the switch, or select the switch in the OA GUI Rack Overview window. Setting the IP address manually...
  • Page 25: Configure The 8Gb San Switch

    Or, follow the onscreen prompts to change your password now. 1 1. The OA will then connect its serial line to the Switch in the specified interconnect bay. A prompt displays indicating that the escape character for returning to the OA is Ctrl __ (underscore).
  • Page 26: Setting The Date And Time

    Setting the date and time The date and time are used for logging events. 8Gb SAN Switch operation does not depend on the date and time; a switch with an incorrect date and time value will function properly.
  • Page 27: Modifying The Fc Domain Id (Optional)

    If desired, you can modify the FC domain ID. The default FC domain ID is domain 1. If the 8Gb SAN Switch is not powered on until after it is connected to the fabric, and the default FC domain ID is already in use, the domain ID for the new switch is automatically reset to a unique value.
  • Page 28: Disabling And Enabling A Port

    If you have not already done so, connect to the switch, and log in as admin, as described in Connect to the Command Line Issue the switchDisable command. All Fibre Channel ports on the switch are taken offline. If the switch was part of a fabric, the fabric reconfigures. To enable:...
  • Page 29: Verifying The Configuration

    Check the LEDs to verify that all components are functional. For information about LED patterns, refer to Enter switchshow to get information about the switch and port status. Interpreting LED activity, page 34 . Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 30: Backing Up The Configuration

    Enter fabricshow to get general information about the fabric. Backing up the configuration To back up the switch configuration to an FTP server, enter configupload and follow the prompts. The configupload command copies the switch configuration to the server, making it available for downloading to a replacement switch, if necessary.
  • Page 31: Managing The 8Gb San Switch

    When running IP over FC, these management tools must be run on both the Fibre Channel host and the switch and must be supported by the Fibre Channel host driver. For a list of Fibre Channel hosts supported by the 8Gb SAN Switch, contact your HP representative.
  • Page 32: Maintaining The 8Gb San Switch

    You can connect a management station to one switch with Ethernet while managing other switches connected to the first switch with FC. To do so, set the FC gateway address of each of the other switches to be managed to the FC IP address of the first switch.
  • Page 33: Diagnostic Tests

    Diagnostic tests can temporarily lock the transmit and receive speed of the links during diagnostic testing. For information about specific diagnostic tests, refer to the latest version of the HP StorageWorks Fabric OS administrator guide, or enter help followed by the name of the diagnostic test.
  • Page 34: Interpreting Led Activity

    NOTE: Each time the 8Gb SAN Switch is powered on, its settings are restored to the last saved configuration. Interpreting LED activity You can monitor switch activity and status by checking 8Gb SAN Switch LEDs. There are three possible LED states: no light, a steady light, or a flashing light. The steady lights and flashing lights can be green or amber.
  • Page 35: Module Status Led Patterns

    Port is disabled as a result of diagnostics or portDisable command. If the LEDs for all ports are slow-flashing amber, the switch could be disabled. Brocade 8Gb SAN Switch for HP BladeSystem c-Class Recommended action Verify that switch is on and completed booting. No action required.
  • Page 36: Post And Boot Specifications

    POST and boot specifications POST is a system check that is performed each time the switch is powered on, rebooted, or reset. During POST, the LEDs flash different colors. Any errors that occur during POST are listed in the error log.
  • Page 37: Firmware Update

    Telnet session or another management tool. If this is not successful, the 8Gb SAN Switch did not successfully complete POST; contact HP. Review the switch system log for errors. Any errors detected during POST are written to the system log, accessible through the errshow command.
  • Page 38: Rebooting The Switch

    To access the guides, scroll to the storage section of the web page, and select Storage Networking for HP StorageWorks products. In addition to these guides, refer to the Brocade 8Gb SAN Switch for HP c‐Class BladeSystem—Setup, Configuration and Installation Procedures available on instructions of the new switch.
  • Page 39 Verify that the switch is joined to the fabric and all connected devices log in to the switch; enter: switchshow Save the configuration file.
  • Page 40 Managing the 8Gb SAN Switch...
  • Page 41: A Regulatory Compliance And Safety

    US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation. This laser product complies with 21 CFR 1040.10 and 1040.1 1 except for editions pursuant to Laser Notice No. 50, dated May 27, 2001; and with IEC 60825-1:1993/A2:2001. Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 42: Certification And Classification Information

    This Class A Digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Regulatory compliance and safety or equivalent may be located on the surface of the HP supplied laser...
  • Page 43: European Union Regulatory Notice

    European union regulatory notice BSMI notice Japanese notice Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 44: Korean Notice

    There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized service provider.
  • Page 45: Power Cords

    18 AWG, and the length of the cord must be between 1.8 m (6 ft) and 3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them.
  • Page 46 Regulatory compliance and safety...
  • Page 47: B Electrostatic Discharge

    Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller.
  • Page 48 Electrostatic discharge...
  • Page 49: C San Switch Technical Specifications

    • Supported SFPs, page 51 • Supported HBAs, page 51 General specifications Table 18 lists general specifications for the 8Gb SAN Switch for HP BladeSystem c-Class. Table 18 General specifications Specification Configurable port types Media types EMC emissions dimensions, page 50...
  • Page 50: Weight And Physical Dimensions

    Depth Weight 1.27 kg (2.8 lb) Environmental requirements To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in operating and nonoperating conditions. Table 20 Environmental requirements...
  • Page 51: Supported Sfps

    SFP will automatically be disabled by switch firmware, leaving the port non-operational. See Supported SFP transceiver For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN design reference guide at the HP website: http://h18000.www1.hp.com/products/storageworks/san/documentation.html.
  • Page 52 SAN Switch technical specifications...
  • Page 53: Glossary

    Software: The set of parameters that guide switch operation. May include general system parameters, IP address information, domain ID, and other information. Modifiable by any login with administrative privileges. May also refer to a set of zones. Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 54 Unique identifier used in routing frames for all switches in a fabric. Usually assigned by the principal switch, but can be assigned manually. The domain ID for an HP switch can be any integer between 1 and 239. The default domain ID is usually 1.
  • Page 55 The fabric created by connecting multiple HP switches with multiple ISL cables, and configuring the switches to handle traffic as a seamless group. ISL trunking The distribution of traffic over the combined bandwidth of multiple ISLs.
  • Page 56 A node port that can operate as an N_Port or NL_Port. Onboard The HP BladeSystem Onboard Administrator (OA) is the enclosure management Administrator processor, subsystem, and firmware base used to support the HP BladeSystem (OA) c7000 or HP BladeSystem c3000 and all the managed devices contained within the enclosure.
  • Page 57 The selection of a transmission path through the fabric. HP switches use the FSPF protocol for transmission path selection. phantom address An AL_PA value assigned to a device that is not physically in the loop. Also known as phantom AL_PA.
  • Page 58 See also ???. U_Port Universal port. A switch port that can operate as a G_Port, E_Port, F_Port, or FL_Port. A port is defined as a U_Port when it is not connected or has not yet assumed a specific function in the fabric. See also ???, ???, ???.
  • Page 59 See also ???, ???. zone configuration A specified set of zones. Enabling a configuration enables all zones in that configuration. See also ???, ???. Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 60 Glossary...
  • Page 61 POST specifications, 36 Power Pack, 15 related documentation, 9, 9 SAN Switch configuration, 25 installing, 20 licensing, 15 maintenance, 32 management features, 31 port diagram, 14 power, 33 transceiver, 25 removing, 32 Brocade 8Gb SAN Switch for HP BladeSystem c-Class...
  • Page 62 51 shipping carton contents, 19 SNMP applications, 31 specifications environmental requirements, 50 general, 49 physical, 50 Subscriber's choice, HP, 1 1 supported HBAs, 51 supported sfp options, 17 supported SFPs, 51 symbols in text, 10 technical support HP, 9...