A A ntenna configuration 4
A A ntenna configuration 5
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
RF600 system planning
4.3 Antenna configurations
D D escription/ application areas
Preferred for the identification of goods
at loading gates: Similar to configuration
2, but with additional reading reliability
when the transponder is at an angle to
the vertical.
Transponder
D D escription/ application areas
Preferred for the identification of goods
at loading gates: The transponder is
located in the radiation field of all four
antennas, so the transponder position for
reliable tag identification is more flexible
than in configuration 2.
Transponder