Surroundings:
Enclosure
1
Enclosure kit available
Vibration test
Max. relative humidity
Aggressive environment (IEC 60721-3-3), coated
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature
Derating for high ambient temperature, see section on special conditions
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
Derating for high altitude, see section on special conditions
Safety standards
EMC standards, Emission
EMC standards, Immunity
See section on special conditions
20
5% - 95%(IEC 60721-3-3; Class 3K3 (non-condensing) during operation
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EN 61800-3, EN 61000-6-1/2, EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
DEH-41264A
AF-60 LP™ Micro Drive
IP 20
IP 21, TYPE 1
1.0 g
class 3C3
Max. 40 °C
0 °C
- 10 °C
-25 - +65/70 °C
1000 m
3000 m
EN/IEC 61800-5-1, UL 508C