3.3 Power supply requirement
Acceptable voltage fluctuation : normally ±10%vlt.
a.
Acceptable frequency fluctuation : ±1HZ (50/60HZ)
b.
Acceptable momentary power-off duration: less than10m.sec
c.
Acceptable voltage impulse
d.
The Peak value : 200% or less than the line voltage of the actual value(rms. value)
Duration: 1.5m.sec or less
Acceptable AC voltage of the waveform distortion.
e.
Acceptable imbalance of the line voltage: 5% or less
f.
g.
Power capacity table
The total power requirement should be 9.753KVA
The total power requirement should be 20.203KVA
The total power requirement should be 22.193KVA
TPR-1230H & TPR-1230
Main Motor
Elevating Motor
Hydraulic Motor
Coolant Pump Motor
TPR-1600H
Main Motor
Elevating Motor
Hydraulic Motor
Coolant Pump Motor
TPR-2000H
Main Motor
Elevating Motor
Hydraulic Motor
Coolant Pump Motor
3-4
2.25Kw
0.75Kw
0.75Kw
0.1Kw
5.625Kw
1.5Kw
0.75Kw
0.1Kw
5.625Kw
2.25Kw
0.75Kw
0.1Kw