Electrolux EVY8840AAX User Manual page 20

Table of Contents

Advertisement

20 www.electrolux.com
12.4 Lamp
WARNING!
There is a risk of electrical shock.
The lamp and the lamp glass cov-
er can be hot.
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
12.5 Cleaning the oven door
Removing the door and the glass panels
You can remove the oven door and the
internal glass panels to clean it. The num-
ber of glass panels is different for different
models.
WARNING!
Be careful when you remove the
door from the appliance. The door
is heavy.
A
A
2.
Remove the metal ring and clean the
glass cover.
3.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
4.
Attach the metal ring to the glass cov-
er.
5.
Install the glass cover.
Replacing the lamp on the left side of
the cavity:
1.
Remove the left shelf support.
2.
Use a Torx 20 screwdriver to remove
the cover.
3.
Remove and clean the metal frame
and the seal.
4.
Replace the lamp with a suitable 300
°C heat-resistant lamp.
5.
Install the metal frame and the seal.
Tighten the screws.
6.
Install the left shelf support.
1.
Open the door fully.
2.
Fully press the clamping levers (A) on
the two door hinges.
3.
Close the oven door to the first open-
ing position (approximately 70° angle).
4.
Hold the door with one hand on each
side and pull it away from the appli-
ance at an up angle.
5.
Put the door with the outer side
down on a soft cloth on a stable sur-
face. This is to prevent scratches.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evy8840aox

Table of Contents